8 ACCEL (ACCELERATION TIME)
ACCEL sets the acceleration rate for all speed reference sources (keypad, speed pot, 4-20
mA, 0-10 VDC, jog, and the preset speeds). The ACCEL setting is the time to accelerate
from 0 Hz to the BASE FREQUENCY (Parameter 18). The range of adjustment for ACCEL
depends on horsepower. Refer to the table below:
Example: If ACCEL is set to 30 seconds, and the BASE FREQUENCY is set to 60 Hz, the
drive will ramp from 0 Hz to 60 Hz in 30 seconds. This is a linear function, therefore the
drive would ramp up to 30 Hz in 15 seconds, etc.
NOTE: The ability to accelerate a given load at a particular rate is limited by the output
power capability of the drive/motor combination. The acceleration of high-inertia and high-
friction loads may be affected by the current limiting characteristics of the drive. See
Parameters: 16 - CURRENT, 19 - FX BOOST, and 20 - AC BOOST for more information.
9 DECEL (DECELERATION TIME)
DECEL sets the deceleration rate for all speed reference sources. The DECEL setting is the
time to decelerate from BASE FREQUENCY to 0 Hz. As with Parameter 8 - ACCEL, this
is a linear function. If the drive is set to coast to a stop, DECEL will have no effect when a
STOP command is given. The range of adjustment for DECEL depends on horsepower,
voltage, and whether Dynamic Braking (DB) is being used. Refer to the table below:
ACCELERATION LIMITS
HORSEPOWER RANGE OF ADJUSTMENT
0.25 - 20 0.1 - 3600 SEC
25 - 60 0.3 - 3600 SEC
DECELERATION LIMITS
HORSEPOWER / VOLTAGE RATING RANGE OF ADJUSTMENT
240 / 200 VAC 480 / 400 VAC 590 / 480 VAC WITHOUT DB WITH DB
(NOTE 1) (NOTE 2)
0.25 - 7.5 HP 1 - 7.5 HP ---- 0.3 - 3600 SEC 0.1 - 3600 SEC
10 - 15 HP 10 - 20 HP 1 - 7.5 HP 0.5 - 3600 SEC 0.1 - 3600 SEC
20 - 30 HP 25 - 60 HP 10 - 20 HP 1.0 - 3600 SEC 0.2 - 3600 SEC
---- ---- 25 - 60 HP 2.0 - 3600 SEC 0.2 - 3600 SEC
NOTE 1: 240/120 Vac units have the same limits as 240/200 Vac units.