Install Instructions

Outer Riser Assembly
Inner Riser Assembly
THREADED PLUG
& ADAPTOR
Optional
FINGER HOLE
THUMB SCREW
NOTCH
INNER RISER PIPE
not included
VALVE BODY
BUSHING
Bushings are provided for PVC
schedule 40x SDR-35 installations
Building
Sewer
FLAPPER ASSEMBLY
FLAPPER
Heavy Duty
Rated at 75 PSI
OUTER RISER PIPE
not included
Extendable Backwater Valve
1
2
3
4
5
6
7
8
9
10
INSTALLATION INSTRUCTIONS
Contact: RectorSeal
®
713-263-8001 800-231-3345 713-263-7577 800-441-0051 www.rectorseal.com
P F W
VALVE BODY
Flow Building
FLOW
OUTER
RISER PIPE
SEWER LATERAL
Outer Riser Installation
At proper depth, install the Clean Check Valve Body
between the building and the sewer lateral, with the “FLOW”
arrow of the Valve Body pointing downstream away
from the building.
Rotate the Valve Body until the opening is facing directly
upward. A level may be used across the top of the Valve Body
to verify horizontal positioning.
Cut the Outer Riser Pipe to the required length. Cement
and insert while keeping the inside of the body clean of debris.
CAUTION: Be certain that excess solvent cement has not
impeded proper seating of the Flapper Assembly or the proper
seating of the apper sealing surface of the Valve Body.
Inner Riser Installation
Cut the Inner Riser Pipe to a length (3-1/2”) shorter than
the Outer Riser Pipe.
Cement the Flapper Assembly to one end of the Inner
Riser Pipe.
Cement the Upper Collar to the other end of the Inner Riser
Pipe, while aligning the center of the Finger Hole with the center
of the Flapper on the opposite end.
When cement is dry, loosen the thumb screw in the Upper Collar
and slide the Inner Riser Assembly – Flapper Assembly rst –
into the Outer Riser Assembly with the at sealing side of the
Flapper facing the inlet side of the Valve Body. Lower the Inner
Riser Assembly into the seating area of the Valve Body, making
certain that the Thumb Screw is inside the inside wall of
the Outer Riser Pipe and NOT on
the resting on the top edge. Seat
the Flapper Assembly by rotating
as necessary until it locks in place.
Visually inspect that the Flapper
Assembly is installed correctly.
IMPORTANT: Prior to installation
of the Threaded Adaptor & Plug
(with the Inner Riser Assembly
properly installed) cut a reference
notch into the Outer Riser Pipe.
This saw cut notch should be
aligned with the molded Notch in
the Upper Collar. For future removal,
alignment of the notches will
quickly indicate that the apper is
seated correctly.
IMPORTANT: Tighten the ¼” Stainless Steel Thumb Screw
until it seats snugly against the Inner Riser Pipe, xing the Inner
Riser Assembly in place.
Cement the Threaded Adapter to the Outer Riser Pipe
riser and screw the Threaded Plug into the
Threaded Adapter to complete installation.
Pre-Installation
Slide Upper Collar through
Outer Riser Pipe. If collar does
not slide freely through pipe,
check to see if pipe is
“out-of-round”. If so, replace
Outer Riser Pipe.
Backwater valves require
adequate drop between the
ood rim of the lowest xture
and burial depth of the valve in
order to function properly.
We recommend a minimum
slope of 1/4” per foot or as
recommended by the UPC
and IPC codes.
Additional PVC bushings are
enclosed for use if needed.
Discard if not used.
Parts not provided
• Standard 8” or 6" ABS or
PVC Outer Riser Pipe of re-
quired length, and one 8" or 6"
Threaded Adaptor & Plug
(8" or 6" Outer Riser Pipe
is determined by the Clean
Check model to be used)
• Standard 4” ABS or PVC
Inner Riser Pipe of required
length.
CHECK ®
CLEAN
EXTENDABLE BACKWATER VALVE
MAINTENANCE GUIDE
REFERENCE
NOTCH
See step 8
RectorSeal brand solvent cements are approved to meet manufacturer’s recommendations.