Install Instructions

Welcome
Thank you for choosing TripleGuard Active system designed to detect water leaks and prevent
the subsequent damages. TripleGuard Active will give you peace of mind.
Please Note
Please read these instructions carefully and follow the system’s installation and commissioning
steps. Maintain this document in a safe place for future reference. Contact your authorized
installer with any questions.
WARNING! This product includes moving parts. Keep your ngers or any other objects away.
WARNING! This product was designed to prevent water leakage damages and should be
used for this purpose only.
TripleGuard Active
The system detects and prevents water leaks. When the leak is detected, the system
disconnectsthe water supply, activating the Shut Off unit. The system is designed to minimize
potential ooding damages by shutting down the water supply when the site is inactive and/or
when a leak indication is received. Each unit is comprised of a Shut Off unit (valve) installed on
the main water supply pipe and leak detector overseeing the closing of the valve. Also, the Shut
Off unit can be deactivated manually. The water system is designed for internal use and should
be installed by an authorized technician.
Shut Off Unit Specication:
Shut Off Unit Description
1. Closing/ opening handle
2. Close/ open indication
3. Entry/ exit 3/4” female thread
4. Battery housing: 2 X CR123
5. Leak Detector
Shut Off Unit (Valve) Installation
Installation and/or replacement of a battery should be performed by authorized personnel.
The Shut Off unit should be located on the main water line incoming into the water heater or
appliance
The system should not disconnect a re extinguishing line or a sprinkler line
Ensure easy access to the battery housing (opened with a screwdriver) - ensure a minimal
access space of 12 inches (30 cm)
The unit should be installed with access to the handle
Manual opening and closing of the valve handle should be possible after installation
The marking of the valve status (Closed/Open) should be clearly read after installation
Shut Off Unit Installation Stages
1. Locate the most suitable place for installation on the water line.
2. Shut down the water supply, using the main valve of the building or site.
3. Cut the water line to install the Active valve.
4. Make sure that the manual disconnection unit can be opened and closed.
5. Enable passage of water in the main line and prevent leaks or drippings.
6. Ensure easy access to the battery housing.
7. If unit wetting is probable, install an external protective casing.
Warranty Instructions
Please visit www.rectorseal.com/tripleguard-support for warranty, technical support, terms, and
conditions or troubleshooting. RectorSeal, LLC warrants the TripleGuard (product only) to be free
of defects in workmanship, and material for a period of up to one year from date of purchase.
TripleGuard Active Installer Guide
Product 97720
RectorSeal
2601 Spenwick Drive - Houston, TX 77055 800-231-3345 rectorseal.com
RectorSeal, the logos and other trademarks are property of RectorSeal, LLC, its afliates or its licensors and are protected by copyright, trademark and other intellectual property laws,
and may not be used without permission. RectorSeal reserves the right to change specications without prior notice. © 2018 RectorSeal. All rights reserved. R50310-0918
4
5
2
3
1
Part Code 97720
Product Description
The All-in-one valve is installed on the main water supply line to
the water heater or appliance.
Material of Construction
Polycarbonate-ABS, PTFE Seals
Body: SS304
Dimensions 5.31 x 4.92 x 2.95 inches (134.87 x 124.97 x 74.93 mm)
Weight 1.75 lbs (793.77 g)
Power Supply Two 3V batteries (CR123)
Operation Voltage 3V
Battery Life Span
Up to four years, subject to the usage prole and valve use
frequency. Manufacturer recommends to visually inspect
batteries every year.
Flood Detector 9.84 ft (3 m) cable length
Standards ISO 9001
Certications NSF372
Pressure Rating 200PSI
Working temperature -4°F to 122°F (-20°C to 50°C)

Summary of content (1 pages)