Specifications
OM-228 921 Page 25
5-7. Activating The Dry Charge Battery (If Applicable)
! Always wear a face shield,
rubber gloves and protective
clothing when working on a
battery.
Remove battery from unit.
1 Vent Caps
2 Sulfuric Acid Electrolyte
(1.265 Specific Gravity)
3 Well
Fill each cell with electrolyte to
bottom of well (maximum).
! Do not overfill battery cells.
Wait ten minutes and check electro-
lyte level. If necessary, add electro-
lyte to raise to proper level. Reins-
tall vent caps.
4 Battery Charger
! Read and follow all instruc-
tions supplied with battery
charger.
5 5 Amperes For 30 Minutes
Charge Time
6 30 Amperes For 12 Minutes
Charge Time
Charge battery. Disconnect charg-
ing cables and install battery.
When electrolyte is low, add
only distilled water to cells to
maintain proper level.
1
Tools Needed:
2
4
+
−
3
drybatt1 2008−01 − S-0886
5
6
30 A
5 A
5-8. Connecting The Battery
1/2 in.
−
+
Tools Needed:
Conn_batt1 2008−02 802 168-E / Ref. 202 705 / 802 313 / S-0756-C
! Connect negative (−) battery
cable last.
Reinstall cover after connecting
battery.