Specifications

OM-228 921 Page 30
5-13. Connecting To Remote 14 Receptacle RC14
OR
804 582-A
Socket* Socket Information
24 VOLTS AC
A 24 volts AC. Protected by
supplementary protector CB5.
B Contact closure to A completes
24 volt AC contactor control
circuit.
REMOTE
OUTPUT
CONTROL
C Output to remote control:+10
volts DC in MIG or Stick mode;
0 to +10 volts DC in TIG mode.
D Remote control circuit common.
E DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
115 VOLTS AC
I
115 volts, 10 amperes, 60 Hz
AC. Protected by supplementa-
ry protector CB13.
J
Contact closure to I completes
115 volt AC contactor control
circuit.
GND
K Chassis common.
NEUTRAL G Circuit common for 24 and 115
volt AC circuit.