Specifications

OM-237 881 Page 17
4-8. Electrical Service Guide
NOTICE − INCORRECT INPUT POWER can damage this welding power source. Phase to ground voltage shall not exceed +10% of rated input
voltage.
NOTICE − Actual input voltage should not be 10% less than minimum and/or 10% more than maximum input voltages listed in table. If actual input
voltage is outside this range, output may not be be available.
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated circuit sized for the rated output and duty cycle of the welding power source.
In dedicated circuit installations, the National Electrical Code (NEC) allows the receptacle or conductor rating to be less than the rating
of the circuit protection device. All components of the circuit must be physically compatible. See NEC articles 210.21, 630.11, and
630.12.
Single-Phase
Input Voltage (V) 208 230 400 460 575
Input Amperes (A) At Rated Output 60.8 54.6 29.7 25.4 19.9
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay Fuses
2
70 60 35 30 25
Normal Operating Fuses
3
80 80 45 40 30
Min Input Conductor Size In AWG/Kcmil
4
8 8 10 12 12
Max Recommended Input Conductor Length In Feet (Meters)
72
(22)
89
(27)
176
(54)
140
(43)
219
(67)
Min Grounding Conductor Size In AWG/Kcmil
4
8 8 10 12 12
Three-Phase
Input Voltage (V) 208 230 400 460 575
Input Amperes (A) At Rated Output 40.4 36.1 20.6 17.8 14.1
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay Fuses
2
45 40 25 20 15
Normal Operating Fuses
3
60 50 30 25 20
Min Input Conductor Size In AWG/Kcmil
4
8 10 12 14 14
Max Recommended Input Conductor Length In Feet (Meters)
119
(36)
96
(29)
175
(53)
150
(46)
234
(71)
Min Grounding Conductor Size In AWG/Kcmil
4
10 10 12 14 14
Reference: 2011 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5”. See UL 248.
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.15(B)(16). If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable
requirements.