ArcPower 360 Table of contents 1. Safety instructions.......................................................................................................... 3 2. Operating determinations............................................................................................... 3 3.Description of the ArcPower 360.................................................................................... 4 4.Installation......................................................................................
CAUTION! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this product has to: - be qualilfied - follow the instructions of this manual CAUTION! Be careful with your operations.
3.
installed following the manufacturer´s instructions.The earth has to be connected! Cord plug connections: Cable Pin International Brown Live L Light blue Neutral N Yellow/Green Earth This device falls under protection class I.Therefore the ArcPower 360 has to be connected to a mains socket outlet with a protective earthing connection. 4.2.Mounting the ArcPower 360 The ArcPower 360 should be be placed on a non-f lammable f lat surface in any orientation and fixed by the 6 screws.
2.RJ45 patch cables category 5 that connect the ArcPower 360 each other are wired 1:1,that is,pins with the same numbers are connected together. Pin 1: Not used Pin 2: Not used Pin 3: Not used Pin 4: Not used Pin 5: Not used Pin 6: Data + Pin 7: Data - Pin 8: GND Pin 1: Not used Pin 2: Not used Pin 3: Not used Pin 4: Not used Pin 5: Not used Pin 6: Data + Pin 7: Data Pin 8: GND 5.Installing instructions. 5.1.DMX operating 1.
Multiple ArcPower 360 installation: Connect the DMX output of the first ArcPower 360 with the DMX input of the next ArcPower 360. Always connect one output with the input of the next ArcPower 360 until all fixtures are connected.In this way,up to 32 fixtures can be chained together. At the last ArcPower 360 the data link has to be terminated with a terminator. A termination plug is simply a RJ45 connector with a 120 Ω resistor between pins Data (–) and Data (+).
5.2.Master-slave operating 1.Unplug from the mains before installation. 2.Connect the LED modules to the fixtures. 3.Connect the DMX output of the master fixture in the data-chain with the DMX input of the first slave. Always connect output with the input of the next slave until all slaves are connected.Up to 32 fixtures can be connected in master/slave chain 4.
5.3. Operating via DyNet protocol 1.Unplug from the mains before installation. 2.Connect LED modules to the fixtures. Connect first fixture to the control panel which uses DyNet protocol (e.g. DLP 8100) 3.Connect the DMX output of the first fixture in a data link with the DMX input of the second fixture. Always connect output with the input of the next fixture until all fixtures are connected.Up to 32 fixtures can be connected in data chain. 4.
A description of each byte in DyNet protocol is the following: Byte 0: 1C - hexadecimal Logical Message Byte 1: 01 - Area Byte 2: 00 – Channel level Byte 3: 80 - Channel Byte 4: ff – Channel Offset Byte 5: 00 – Fade Rate Byte 6: FF Byte 7: 1C Checksum (fixed value) (fixed value) Area - (0 to 255), as set on the Arcpower to give a unique address for each Arcpower unit (i.e.
6.ArcPower 360 - Control menu map Default settings=Bold print 001 (001-470) PrG E.P.1 E.P.2 E.P.3 P.01 : P.06 Aut (OFF,On) EdI. E.P.1 E.P.2 E.P.3 S.01 : S.30 End rE1 (0-255) : : FA.t.(0-255) S.tI. (0-255) COP. MAn. rE1. (0-255) Gr1. (0-255) bL1. (0-255) : MAC. (0-255) Str. (0-255) diM. (0-255) tSt St.A. MSt. SLA. E.P.
7.ArcPower 360-DMX protocol Version 2.0 (software version 5.
Mode/Channel 1 2 3 4 5 Value Function Type of control ZONE 7 19 20 21 25 26 27 28 25 26 27 28 1 2 3 - 1 2 3 4 0-255 Red LED 7 Red LED saturation control (0-100%) proportional 0-255 Green LED 7 Green LED saturation control (0-100%) proportional 0-255 Blue LED 7 Blue LED saturation control (0-100%) proportional 0-255 White LED 7 White LED saturation control (0-100%) proportional ZONE 8 22 29 29 1 1 23 30 30 2 2 24 - 31 32 31 32 3 - 3 4 0-255 Red LED 8 Red LED saturatio
Mode/Channel 1 - 2 - 3 4 41 - - 42 - - 43 - - 4 5 Value Function Type of control 184-191 192-199 200-207 208-215 216-223 224-231 232-239 240-247 248-255 Macro 23 Macro 24 Macro 25 Macro 26 Macro 27 Macro 28 Macro 29 Macro 30 Rainbow effect with variable speed step step step step step step step step proportional 0-31 32-63 64-95 96-127 128-143 144-159 160-191 192-223 224-255 Shutter/Strobe Shutter closed Shutter open Strobe-effect from slow to fast Shutter open Opening pulses in seque
8.Control board The control panel situated on the top cover of the ArcPower 360 allows DMX addressing,calling Built-in programs and setting the fixture behaviour Control elements: [ENTER] button- enters menu,confirms adjusted values and leaves menu. , [UP] button and[DOWN] button- moves between menu items on the the same level, sets values. In order to leave the menu without saving value,press [UP] and [DOWN ] at the same time.
1. Enter "EdI." menu 2. Press [UP] or [DOWN] to select the desired program which you wish to edit and press [ENTER]. 3. Press [UP] or [DOWN] to select the desired program step ("S.01" - "S.30") and press [ENTER]. 4. Press [UP] or [DOWN] to select the desired item and press [ENTER]-button.Now you can edit by using [UP] or [DOWN] buttons the DMX values selected item (the list of items depends on selected DMX mode): "End" - a total number of the program steps (value 1-30).
8.4 Test sequences Use the item to run a special demo-test sequences without an external controller,which will show you some possibilities of using the fixture. 8.5 Stand-alone mode Select this menu to set fixture behaviour in stand-alone mode without an external controller. Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master ("MSt") and the rest as the slaves ("SLA").Only one fixture can be set as the master.
Prt --- Protocol selection - Selects a required communication protocol. dMH - the fixture will communicate using DMX 512 signal. dYn - the fixture will communicate using the DyNet protocol. d.On. --- Display permanent on - If this item is set On, the fixture´s display lights permanent. If this item is OFF, the display will be extinguished 2 minutes after last button pressing. SA.d. --- Safe as default - If you press this item, the current DMX value for each effect will be saved to driver´s memory.
9.Control of the ArcPower 360 via RS-232 9.
Type 1: Selection of the preset colours The syntax of the command is: zone Z red; zone Z green; zone Z blue; zone Z white; zone Z yellow; zone Z cyan; zone Z magenta; zone Z blackout; Z ...........means number of the zone (0-9) red/green/blue/white/yellow/cyan/magenta....determines colour blackout.......closes light output ;.............means end of character sequence Examples: zone 3 green; zone 0 blackout; Type 2: Colour mixing-RGB The syntax of the command is: zone Z r,g,b; Z............
10.Technical Specifications: Power supply: Input Voltage: 100-240 V AC, 50/60 Hz Fuse:T 8 A H Max.Pover Consumption:840 VA Input: Control:DMX 512 or Dynet protocol DMX connection:RJ45 RS 232 connection:9-pin D connector Output: Max.Output Voltage:48V DC Max.Output current:350mA per colour Max.
Weight: 6.3 kg Operating temperature: -10°C/+40°C Accessories: Cable joiner (No.13050691)...............10 pcs Optional accessories: Adaptor RJ45/DMX 3 pin.......No.13050730 Adaptor RJ45/DMX 5 pin.......No.13050731 11. Replacing the fuse 1.Before replacing the fuse, unplug mains lead! 2.Unscrew the fuse holder on the rear side of the ArcPower 360 with a fitting screwdriver from the housing (anti-clockwise). 3.Remove the old fuse from the fuse holder. 4.Install the new fuse in the fuse holder. 5.