Stop Timer at 02, Auto Reset to Zero at 02 End, 01 and 02 TimedAuto Reset to Preset 2 at 02 End, 01 off at 02, 02 Timed -- 3918
Stop Timer at 02, Auto Reset to Preset 2, 01 off at 02, 02 TimedAuto Reset to Preset 2 at 02 End, 01 and 02 Timed -- 3817
Stop Timer at 02, Auto Reset to Preset 2, 01 off at 02, 02 LatchedAuto Reset to Zero at 02 End, 01 off at 02, 02 Timed -- 3716
Stop Timer at 02, Auto Reset to Preset 2, 01 and 02 TimedAuto Reset to Zero at 02 End, 01 and 02 Timed -- 3615
Stop Timer at 02, Auto Reset to Preset 2, 01 Timed, 02 LatchedAuto Reset to Preset 2, 01 off at 02, 02 Timed -- 3514
Stop Timer at 02, Auto Reset to Preset 2, Latched OutputsAuto Reset to Preset 2, 01 and 02 Timed -- 3413
Stop Timer at 02, Auto Reset to Zero, 01 off at 02, 02 TimedAuto Reset to Zero, 01 off at 02, 02 Timed -- 3312
Stop Timer at 02, Auto Reset to Zero, 01 off at 02, 02 LatchedAuto Reset to Zero, 01 and 02 Timed -- 3211
Stop Timer at 02, Auto Reset to Zero, 01 and 02 TimedManual Reset to Preset 2, 01 off at 02, 02 Timed -- 3110
Stop Timer at 02, Auto Reset to Zero, 01 Timed, 02 LatchedManual Reset to Preset 2, 01 off at 02, 02 Latched -- 309
DUAL PRESET OPERATING MODES
Stop Timer at 02, Auto Reset to Zero, Latched OutputsManual Reset to Preset 2, 01 and 02 Timed -- 298
Stop Timer at 02, Auto Reset to Preset 2 at 02 End, 01 off at 02, 02 TimedStop Timer at 02, Manual Reset to Zero, 01 and 02 Timed
Stop Timer at 02, Manual Reset to Preset 2, 01 off at 02, 02 TimedManual Reset to Preset 2, 01 Timed, 02 Latched
--
--
4221
287
Stop Timer at 02, Auto Reset to Preset 2 at 02 End, 01 and 02 TimedStop Timer at 02, Manual Reset to Zero, 01 Timed, 02 Latched
Stop Timer at 02, Manual Reset to Preset 2, 01 off at 02, 02 LatchedManual Reset to Preset 2, Latched Outputs
--
--
4120
276
Stop Timer at 02, Auto Reset to Zero at 02 End, 01 off at 02, 02 TimedStop Timer at 02, Manual Reset to Zero, Latched Outputs
Stop Timer at 02, Manual Reset to Preset 2, 01 and 02 TimedManual Reset to Zero, 01 off at 02, 02 Timed
--
--
4019
265
Stop Timer at 02, Manual Reset to Preset 2, 01 Timed, 02 LatchedManual Reset to Zero, 01 off at 02, 02 Latched --4
Stop Timer at 02, Manual Reset to Preset 2, Latched OutputsManual Reset to Zero, 01 and 02 Timed -- 243
Stop Timer at 02, Manual Reset to Zero, 01 off at 02, 02 TimedManual Reset to Zero, 01 Timed, 02 Latched -- 232
Stop Timer at 02, Manual Reset to Zero, 01 off at 02, 02 LatchedManual Reset to Zero, Latched Outputs -- 221
25
Stop Timer at 01, Auto Reset to Preset at 01 End, Timed Output
Stop Timer at 01, Auto Reset to Zero at 01 End, Timed Output
Stop Timer at 01, Auto Reset to Preset, Timed Output
Stop Timer at 01, Auto Reset to Preset, Latched Output
Stop Timer at 01, Auto Reset to Zero, Timed Output
Stop Timer at 01, Auto Reset to Zero, Latched Output
-18
-17
-16
-15
-14
-13
-12
-
11
-
Stop Timer at 01, Manual Reset to Preset, Timed Output
Stop Timer at 01, Manual Reset to Preset, Latched Output
Stop Timer at 01, Manual Reset to Zero, Timed Output
SINGLE PRESET OPERATING MODES
Stop Timer at 01, Manual Reset to Zero, Latched Output-9
10
Auto Reset to Preset at 01 End, Timed Output-8
Auto Reset to Zero at 01 End, Timed Output-7
Auto Reset to Preset, Timed Output-6
Auto Reset to Zero, Timed Output-5
Manual Reset to Preset, Timed Output-4
Manual Reset to Preset, Latched Output-3
Manual Reset to Zero, Timed Output-2
Manual Reset to Zero, Latched Output-1
Programmable Operating Modes -
These modes determine the operational characteristics of the timer. In the
tables, 01 and 02 refer to Output 1 and Output 2 respectively.
MULTIPLE UNIT STACKING
The C48T is designed for close spacing of multiple units. Units can be
stacked either horizontally or vertically. For vertical stacking, install the panel
latch with the screws to the sides of the unit. For horizontal stacking, the panel
latch screws should be at the top and bottom of the unit. The minimum spacing
from center line to center line of the units is 1.96" (49.8 mm). This spacing is
the same for vertical or horizontal stacking.
Note: When stacking units, provide adequate panel ventilation to ensure that the
maximum operating temperature range is not exceeded.
PANEL CUT-OUT SPACING FOR MULTIPLE UNIT STACKING.
HORIZONTAL ARRANGEMENT SHOWN.
PANEL LATCH INSTALLED FOR VERTICAL
UNIT STACKING
PANEL LATCH INSTALLED FOR
HORIZONTAL UNIT STACKING