LCD, POSITIVE REFLECTIVE OR NEGATIVE TRANSMISSIVE
WITH YELLOW/GREEN OR RED LED BACKLIGHTING
INTERNAL LITHIUM BATTERY PROVIDES UP TO 6 YEARS OF
UNINTERRUPTED OPERATION
NEMA 4X/IP65 SEALED FRONT BEZEL
FRONT PANEL RESET, REMOTE RESET, OR BOTH
COUNT SPEEDS UP TO 5 KHz
WIRE CONNECTION MADE VIA SCREW CLAMP TYPE
TERMINALS
DESCRIPTION
The CUB4 offers a large display in a miniature package with a choice of three
displays; reflective, red backlight or green backlight.
The backlight versions require power from an external 9–28 VDC supply. The
optional power supply (MLPS) is designed to be attached directly to the rear of
the CUB4 and is powered from an 85–250 VAC source.
The CUB4 series has a lightweight, high impact plastic case with a clear
viewing window. The sealed front panel with the silicone rubber reset button
meets NEMA 4X/IP65 specifications for wash-down and/or dusty environments,
when properly installed.
ORDERING INFORMATION
MODEL NO. DESCRIPTION PART NUMBERS
CUB4L
(6-digit)
Counter Positive Image Reflective CUB4L000
Counter w/Yel-Grn Backlighting CUB4L010
Counter w/Red Backlighting CUB4L020
CUB4L8
(8-digit)
Counter Positive Image Reflective CUB4L800
Counter w/Yel-Grn Backlighting CUB4L810
Counter w/Red Backlighting CUB4L820
MLPS
+12 VDC Micro-Line Power Supply, 85 to 250 VAC
source, 400 mA max out
MLPS1000
+24 VDC Micro-Line Power Supply, 85 to 250 VAC
source, 200 mA max out
MLPS2000
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
SPECIFICATIONS
1. DISPLAY:
CUB4L: 6-Digit, LCD, 0.48" (12.2 mm) high digits.
CUB4L8: 8-Digit, LCD, 0.46" (11.7 mm) high digits.
2. POWER SOURCE: Internal 3.6 V lithium battery will provide up to 6 years
of continuous operation (high speed counting and extreme temperatures will
decrease battery life).
3. BACKLIGHT POWER REQUIREMENTS: 9 to 28 VDC, 30 mA typical,
50 mA max. Above 26 VDC, derate operating temperature to 50°C.
Must use an RLC model MLPS or an NEC Class 2 or Limited Power Source
(LPS) rated power supply.
4. COUNT INPUT:
SNK mode (DIP switch 1 off, internal pull-up to battery)
V
IN
High Min = 1.25 VDC; V
IN
Low Max = 0.45 VDC
I
IN
Max = 5 µA; V
IN
Max = 3.6 VDC
Count Speed: (count on negative edge)
High freq mode (DIP switch 2 off): max 5 kHz @ 50% duty cycle
Low freq mode (DIP switch 2 on): max 50 Hz @ 50% duty cycle
SRC mode (DIP switch 1 on, internal 20 kW pull-down to common)
V
IN
High Min = 1.25 VDC; V
IN
Low Max = 0.45 VDC
I
IN
Max = 5 mA; V
IN
Max = 28 VDC
Count Speed: (count on negative edge)
High freq mode (DIP switch 2 off): max 5 kHz @ 50% duty cycle
Low freq mode (DIP switch 2 on): max 50 Hz @ 50% duty cycle
5. RESET INPUT:
V
IN
Low Max = 1.5 VDC (internal pull-up to battery)
I
IN
Max = 20 µA
5 msec min (active low for count reset to zero)
6. ENVIRONMENTAL CONDITIONS:
Operating Temperature: 0 to 60°C (above 50°C, derate backlight operating
voltage to 26 VDC max.).
Storage Temperature: -30 to 85°C
Operating and Storage Humidity: 85% max. (non-condensing) from 0°C
to 50°C.
Vibration to IEC 68-2-6: 5 to 500 Hz, 5 g.
Shock to IEC 68-2-27: Operational 30 g.
Altitude: Up to 2000 meters
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
MODEL CUB4L & CUB4L8 - MINIATURE ELECTRONIC COUNTERS
DIMENSIONS In inches (mm)
2.95 (74.9)
1.54 (39.1) 1.29 (32.8)
0.15 (3.8)
1.36 (34.5)
0.13 (3.2)
2.68
(68 )
1.30
(33 )
+.024
-.000
+.6
-.0
+.025
-.000
+.6
-.0
Bulletin No. CUB4L-C
Drawing No. LP0793
Released 06/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
Note: Recommended minimum clearance (behind the panel) for mounting clip
installation is 2.15" (54.6) H x 3.00" (76.2) W.
PANEL CUT-OUT