Manual

4
2.0 INSTALLING THE DISPLAY
EPAX DISPLAY INSTALLATION
The EPAX display is intended to be mounted
into a panel or enclosure. The display is provided
with a gasket to provide a water-tight seal. The
recommended minimum panel thickness for
NEMA 4/IP65 sealing is 0.060" (1.57 mm).
For panel mounting, prepare the panel
cut-out to the dimensions shown in
Figure 3. The supplied template may be
used to mark the cut-out and hole
locations on the panel. After the panel
cut-out has been deburred, slide the
panel gasket over the rear of the display
and onto the mounting studs. Insert the
display into the panel cut-out as
illustrated in Figure 4. Install 14 # 10-32
keps nuts (supplied) and tighten evenly
for uniform gasket compression. Do not
over-tighten the nuts.
By using additional mounting accessories,
the EPAX can be surface-wall mounted,
suspended, or bottom mounted. Separate installation
instructions are provided with the mounting accessories.
Environment And Cleaning
The display should be installed in a location that does not exceed
the maximum operating temperature and provides good air
circulation. Placing the system near devices that generate
excessive heat should be avoided.
The bezel should be cleaned only with a soft cloth and
neutral soap product. Do NOT use solvents. Continuous
exposure to direct sunlight may accelerate the aging
process of the bezel.
Figure 4, Installing The EPAX Into A Panel
Figure 3, Panel Cut-out for the EPAX
DIMENSIONS In inches (mm)