Owner manual

33
TROUBLESHOOTING
PROBLEM REMEDIES
No Display At Power-Up Check power level and power connections
No Display After Power-Up
Check Module 3: d-LEU, d-Cont, and LINE 1 program settings.
Program Locked-Out
Check for Active User Input, programmed for PLOC. Deactivate User Input.
Enter proper access code at COdE 0 prompt.
No Line 1 Display
Check Module 3: LINE 1 program setting.
No Line 2 Display Check Module 3: ACCESS program settings.
No Programmable Units Display
Check Module 3: UNItS Mnemonic program settings.
Incorrect Input Display Value Check Input Jumper Setting, Input Level, and Input Connections.
Verify Module 1 program settings.
Contact factory
Display of OLOL, ULUL, Short, OPEN, or “ . . . . See General Meter Specifications, Display Messages.
Modules or Parameters Not Accessible Check for corresponding plug-in option card.
Verify parameter is valid in regard to previous program settings.
Error Code: ErrKEY Keypad is active at power up. Check for depressed or stuck keypad. Press
any key to clear Error Code.
Error Code: EE PAr
Error Code: EE Pdn
Parameter Data Checksum Error. Press any key to clear Error Code, verify
all program settings and cycle power. Contact factory if Error Code returns at
next power-up.
Error Code: ErrPro Parameter Data Validation Error. Press any key to clear Error Code, verify all
program settings and cycle power. Contact factory if Error Code returns at
next power-up.
Error Code: EE CAL Calibration Data Validation Error. Contact factory.
Error Code: EE Lin Linear Output Card Data Validation Error. Press any key to clear Error Code
and cycle power. If Error Code returns at next power-up, replace Linear
Option Card or contact factory.
PARAMETER VALUE CHART Programmer ________________ Date ________
PAX2A Meter# _____________ Security Code ________
1-InPUt INPUT SETUP PARAMETERS
DISPLAY PARAMETER USER SETTING
rANgE
INPUT RANGE
SCALE
TEMPERATURE SCALE
ICE
ICE POINT CONPENSATION
rAtE
ADC CONVERSION RATE
dECPNt
SCALING DECIMAL POINT
round
DISPLAY ROUNDING
OFFSEt
DISPLAY OFFSET
FILtEr
DIGITAL FILTER
bANd
DIGITAL FILTER BAND
POINtS
SCALING POINTS
StYLE
SCALING STYLE
INPUt 1
INPUT 1 SCALING VALUE
dISPLY 1
DISPLAY 1 VALUE
INPUt 2
INPUT 2 SCALING VALUE
dISPLY 2
DISPLAY 2 VALUE
INPUt 3
INPUT 3 SCALING VALUE
dISPLY 3
DISPLAY 3 VALUE
INPUt 4
INPUT 4 SCALING VALUE
dISPLY 4
DISPLAY 4 VALUE
INPUt 5
INPUT 5 SCALING VALUE
dISPLY 5
DISPLAY 5 VALUE
INPUt 6
INPUT 6 SCALING VALUE
dISPLY 6
DISPLAY 6 VALUE
DISPLAY PARAMETER USER SETTING
INPUt 7
INPUT 7 SCALING VALUE
dISPLY 7
DISPLAY 7 VALUE
INPUt 8
INPUT 8 SCALING VALUE
dISPLY 8
DISPLAY 8 VALUE
INPUt 9
INPUT 9 SCALING VALUE
dISPLY 9
DISPLAY 9 VALUE
INPUt 10
INPUT 10 SCALING VALUE
dISPLY 10
DISPLAY 10 VALUE
INPUt 11
INPUT 11 SCALING VALUE
dISPLY 11
DISPLAY 11 VALUE
INPUt 12
INPUT 12 SCALING VALUE
dISPLY 12
DISPLAY 12 VALUE
INPUt 13
INPUT 13 SCALING VALUE
dISPLY 13
DISPLAY 13 VALUE
INPUt 14
INPUT 14 SCALING VALUE
dISPLY 14
DISPLAY 14 VALUE
INPUt 15
INPUT 15 SCALING VALUE
dISPLY 15
DISPLAY 15 VALUE
INPUt 16
INPUT 16 SCALING VALUE
dISPLY 16
DISPLAY 16 VALUE
ScLISt
ENABLE SCALE LIST