User guide

1818
3-DRAWINGS AND TECHNICAL SPECIFICATIONS3-DRAWINGS AND TECHNICAL SPECIFICATIONS
TECHNICAL CHARACTERISTICS COMPACT 18 HYDRO COMPACT 24 HYDRO
Product class (EN 303-5:2012): 5 5
Nominal thermal power to rebox: 18,1 kW (15566 kcal/h) 24,5 kW (21070 kcal/h)
(Max) nominal output power: 17,0 kW (14620 kcal/h) 22,1 kW (19006 kcal/h)
Minimum output power 3,8 kW (3268 kcal/h) 3,8 kW (3268 kcal/h)
Eciency at Max 93,8% 90,2%
Eciency at Min 88,5% 88,5%
Temperature of exhaust smoke at Max 110 °C 150°C
Temperature of exhaust smoke at Min 60 °C 60°C
Maximum temperature that can be set 80 °C 80 °C
Maximum operating temperature 95 °C 95 °C
Particulate/OGC / Nox (13%O
2
) 39,6 mg/Nm
3
- 3,8 mg/Nm
3
- 186 mg/Nm
3
24 mg/Nm
3
- 0,1 mg/Nm
3
- 181 mg/Nm
3
CO at 10% O
2
at Min and at Max 0,027% – 0,019% 0,027 - 0,013%
CO
2
at Min and at Max 5,9% - 9,2% 5,9 - 9,0%
Recommended draught at Max power 0.10 mbar - 10 Pa 0.10 mbar - 10 Pa
Recommended draught at Min power 0.05 mbar - 5 Pa 0.05 mbar - 5 Pa
Mass of smoke 12.7 g/sec 17.5 g/sec
Hopper capacity 100 litres 100 litres
Type of pellet fuel Pellet diameter 6-8 mm and size 5/30 mm Pellet diameter 6-8 mm and size 5/30 mm
Pellet hourly consumption Min ~ 1 kg/h* - Max ~ 3.6 kg/h* Min ~ 1 kg/h* - Max ~ 4.8 kg/h*
Autonomy At min ~ 68 h* - At max ~ 19 h* At min ~ 68 h* - At max ~ 15 h*
Heatable volume m3 366/40 - 418/35 - 487/30 475/40 - 543/35 - 634/30
Water content 25 litres 25 litres
Maximum operating pressure 3 bar - 300 kPa 3 bar - 300 kPa
Combustion air inlet External diameter 80 mm External diameter 80 mm
Smoke outlet External diameter 100 mm External diameter 100 mm
Air inlet 100 cm
2
100 cm
2
Nominal electrical power (EN 60335-1). 180 W (Max 430 W) 180 W (Max 430 W)
Supply voltage and frequency 230 Volt / 50 Hz 230 Volt / 50 Hz
Net weight 200 kg 200 kg
Weight with packaging 220 kg 220 kg
* Data that may vary depending on the type of pellets used.
**Heatable volume based on the requested power per m3 (respectively 40-35-30 Kcal/h per m3)