User guide

3333
8-MENU ITEMS AND OPERATION8-MENU ITEMS AND OPERATION
Technical Dept. - All rights reserved - Reproduction is prohibited
SETTINGS MENU
The SETTINGS menu allows to act on the boiler operating mode:
a. Language.
b. Cleaning (displayed only when the boiler is switched o).
c. Feed screw loading (displayed only when the boiler is switched o).
d. Tones.
e. External thermostat (activation).
f. Auto Eco (activation).
g. Eco-Shutdown T (default 10 minutes).
h. pump on T (default 50°C).
i. Auxiliary boiler (default deactivated).
j. Pellet recipe.
k. Smoke rpm % ventilation.
l. Maximum power (1-5 - default 5).
m. Components test (displayed only when the boiler is switched o)
n. Chimney sweep” function (activated only when the boiler is switched on, for eld emissions test).
o. System conguration (factory setting: system 02).
p. Season.
q. Technical menu.
NOTE: Some of the items listed above cannot be activated in certain system congurations”.
a - Language
To select the language act as follows:
• Press the “menu button.
• Scroll to “Settings” using the arrows
• Press “menu to conrm.
• Scroll to “language” using the arrows.
• Press “menu to conrm.
• With the + - keys select the language of interest (IT/EN/DE/FR/ES/NL/PL/DA)
• Press “menu to conrm and esc to exit.
b - Cleaning
To select “Cleaning (only when the boiler is switched o) act as follows:
• Press the “menu button.
• Scroll to “Settings” using the arrows
• Press “menu to conrm.
• Scroll to “Cleaning” using the arrows.
• Press “menu to conrm.
• Select “On” with the + - keys.
• Press “menu to conrm and esc to exit.