i - Auxiliary boiler
One must install an additional module (optional) to enable start-up of an auxiliary boiler in the event the boiler is switched o or in alarm
conditions. By default this function is deactivated, if needed activate it to access the settings menu.
l - Pellet Recipe
One must install an additional module (optional) to enable start-up of an auxiliary boiler in the event the boiler is switched o or in
alarm conditions. By default this function is deactivated, if needed activate it to access the settings menu. This function is for adapting the
boiler to the pellets that are being used. In fact, as there are several types of pellets on the market, boiler operation is extremely variable
depending on the fuel quality. In the event the pellets tend to clog the brazier due to an excessive load of fuel or in the event the ame is
always high even at low powers and, vice versa if the ame is low one can decrease/increase the amount of pellets in the brazier:
The available values are:
-3 = Decrease by 30% compared to factory settings.
-2 = Decrease by 20% compared to factory settings.
-1 = Decrease by 10% compared to factory settings.
0 = No variation.
1 = Increase by 5% compared to factory settings.
2 = Increase by 10% compared to factory settings.
3 = Increase by 15% compared to factory settings.
To change the recipe act as follows:
• Press the “menu” button.
• Scroll to “Settings” using the arrows
• Press “menu” to conrm.
• Scroll to “Pellet recipe” using the arrows.
• Press “menu” to conrm.
• Modify the % with the + - keys.
• Press “menu” to conrm and “esc” to exit
m - Smoke rpm % ventilation
If the installation presents diculties for smoke evacuation (no draught or no pressure in the duct), the smoke and ash expulsion speed
can be increased. This change resolves all the potential problems related to pellets clogging in the brazier and deposits forming at the
bottom of the brazier itself caused by poor quality fuel or fuel that produces a lot of ashes. The values available are from -30% to +50%
with variations of 10 percentage points at a time. The variation in negative can be used in case the ame is too low
To change the parameter act as follows:
• Press the “menu” button.
• Scroll to “Settings” using the arrows
• Press “menu” to conrm.
• Scroll to “Smoke rpm variation” using the arrows.
• Press “menu” to conrm.
• Modify the % with the + - keys.
• Press “menu” to conrm and “esc” to exit