PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN
CLEANING THE EXCHANGER AND PIPE UNIT
CLEANING THE UPPER COMPARTMENT
When the boiler is cold lift front cover H, remove screws O to the right and left and remove cover A. Then remove the the xing screws
from drivers “V and remove boiler cover B”.
At this point, remove the four turbulators C and using a rigid rod or a bottle brush, clean the internal pipe unit and the turbulators,
removing all of the accumulated ash.
Check the cover gasket and replace it if necessary.
ATTENTION: It is advisable to carry out the cleaning of the upper exchanger at the end of the season and possibly by
an authorised technician in order to also replace the gasket located below plug “B”.
CLEANING THE LOWER COMPARTMENT
Remove ash pan D and empty it.
Lower lever “E and extract drawer F. Remove the ash from the drawer and if needed use a vacuum cleaner to remove any other ash or
soot that has built-up under the drawer. Remove brazier G and clean it every 2/3 days. Check the seal of the ceramic bre gasket on the