10-MAINTENANCE AND CLEANING
Technical Dept. - All rights reserved - Reproduction is prohibited
CLEAN THE EXCHANGER AND THE UNDERGRATE SPACE EVERY 2/3 DAYS
Cleaning the exchanger and the undergrate space is a simple operation but very important for always maintaining performance as
declared.
Therefore we recommend cleaning the internal exchanger every 2-3 days, performing these simple operations in sequence:
• Activate the “CLEANING” function – when the boiler is switched of press - menu, select“Settings”, with the <> arrows select
“Cleaning, conrm with “Menu”, activate cleaning “ON” by pressing the +- keys. This procedure activates the smoke extraction fan
on maximum power to expel the soot that is dislodged when the exchanger is cleaned.
• Cleaning the pipe unit – Use the handle for cleaning, located under the front cover, illustrated by the arrow in the drawing, shake
the handle approximately 5 times forwards and backwards. This will remove any soot that has deposited on the exchanger smoke
ducts during normal boiler operation.
• Disable the "CLEANING" function - this function is automatically disabled after two minutes. If one needs to stop this function
in advance press the "Esc" key.
• Clean the smoke conveyor compartment (g.2) - The boiler is tted with three removable pans to clean out the ash, designed
to collect any soot and ash build-up. To empty the pan F it is necessary to grasp the handle E, lower it and pull the drawer outwards.
To empty pans H it is necessary to turn the two hooks on the front of the pan and pull towards yourself.
• When cleaning is nished, close the cover back up and put the ash pans back in place H and F.
If such cleaning is not done every 2-3 days the boiler could go into alarm caused by ash clogging after several hours
of operation.
Figure 1 Figure 2
HANDLE TO CLEAN PIPE UNIT