10-MAINTENANCE AND CLEANING
END-OF-SEASON SHUTDOWN
At the end of season, before shutting down the boiler, we recommend completely removing pellets from the hopper with the use of a
vacuum cleaner with an extension.
The service fuse may have to be replaced if the control panel display does not go on when the product is re-started upon pressing the main
switch on the rear of the boiler.
On the rear of the boiler there is a fuse compartment which is located underneath the supply socket. Use a screwdriver to open the fuse
compartment and if necessary replace them (3.15 A delayed).
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualied personnel whose technical expertise
includes combustion and electricity.
It is recommended to perform this routine maintenance annually (with a scheduled service contract), which focuses on a visual and
functional verication of the internal components. The following is a summary of the necessary checks and/or maintenance for the
product to work correctly.
• Gear motor
• Smoke expulsion fan
• Smoke probe
• Start-up spark plug
• Automatic resettable pellet/water thermostat
• Room/water probe
• Motherboard
• Panel - motherboard protection fuses
• Cabling