BACK FOCUS ADJUSTMENT
WARNING: There is a Screw-In metal plug installed in the camera body covering the back focus screw. This
plug must be removed before performing a back focus adjustment. To remove the plug, use a T-10 Torx
SCREWdriver.
NOTE: To perform this procedure as written, you must have a PL mount and RED Focus™.
Back focus is adjusted by turning the back focus adjustment on the top of the camera’s front plate using a
T-10 Torx screwdriver. This screw is indicated by a Siemens Star with an arrow pointing to its location.
Back Focus Adjustment Location
1.
Remove the screw-in plug located in the back focus adjustment opening using a T-10 Torx screwdriver.
2.
Place the camera on a level, stable surface or mount the camera on a tripod.
3.
Install RED Focus to the camera PL mount.
A.
Remove the camera lens or sensor cover if equipped.
B.
Install RED Focus onto the camera in the position shown.
C.
Ensure RED Focus is secured to the camera with the camera lock ring.
RED Focus Properly Installed on Camera
4.
Power up the camera.
5.
Power up RED Focus. Refer to POWER UP / DOWN.
NOTE: Remember that RED Focus will AUTOMATICALLY power down after 3 minutes. Press the Red button
on the front to power back up.