Operation Manual

RED EPIC OPERATION GUIDE
COPYRIGHT © 2013 RED.COM, INC
955-0002_v4.0, Rev-A | 49
ICON Behavior
CAL:T/E
T or E Green - No change in sensor temperature or exposure from the levels recorded during calibration
T or E Yellow - Slight change in sensor temperature or exposure from the levels recorded during calibration
T or E Red - Significant change in sensor temperature or exposure from the levels recorded during
calibration
The - and + indicate whether the sensor temperature or exposure has decreased or increased
NOTE: The T and E change colors independently of each other.
TC
TC Gray - No analog time code is currently detected
TC Red - Analog time code is being detected, but the use of it is not enabled
TC Green - Analog time code is being used to jam the time of day time code. TC will revert to gray if the
signal is no longer detected
GEN
GEN Gray - No genlock signal is currently detected, or the presented signal cannot crosslock to project
(24.00 fps vs. 23.98 fps)
GEN Red - During process of sync, or if genlock is lost while recording
GEN Green - A genlock signal matching the current HD-SDI monitor rate has been locked to it
GEN Yellow - When timing is cross-locking to compatible but not matching monitor rate. i.e. genlock =
24.00, HD-SDI monitor rate = 25.00
NOTE: 3D operation should not be done if GEN is yellow. This is a warning that genlock source settings and
camera settings are not aligned. Phasing of the sync between cameras cannot be guaranteed when GEN is
yellow.
SYNC
SYNC Gray - The sensor sync mode is not Genlock
SYNC Red - The sensor sync mode is Genlock, but it is not locked to any genlock signal, or genlock or
sensor sync is lost while recording
SYNC Green - A genlock signal compatible with the HD-SDI monitor rate has been locked to and the sensor
timing is also locked to it
POWER STATUS
If powering camera through DC power, the current voltage will be displayed. If using batteries, the remaining
battery time displays.
If using a REDBRICK or similar external battery to power the camera through DC IN, power status displays