Installation manual

34
4-OPERATION
OPERATION WITH ECO-STOP
The Eco-Stop function automatically switches the stove o when the room temperature is met and restarts when it varies.
Activation: briey press the On/O button 5 times consecutively within 6”. The board emits a long beep as conrmation (3 seconds).
• During operation with the Eco-Stop function. The green LED does not remain constantly on but light up for 5 seconds and goes o
for 2 seconds.
• When the temperature is reached (probe temperature on the stove is met and the contact of any external thermostat is open),
the stove enters the Eco-Stop timer phase that involves the gradual passage in Power 1, which remains so for 20 s and if the set
temperature is then still met, shutdown begins. If the temperature varies for a few seconds during the above-mentioned 20 s,
thereby excluding a temporary signal, the timer resets immediately.
• When being shutdown due to Eco-Stop, the LED ashes alternately orange and green every 2”.
• When in stand by due to Eco-Stop, the LED ashes alternately orange and green every 2”.
• The stove is restarted due to the Eco-Stop when the following conditions occur:
• at least 5 s have elapsed from when shutdown began;
• the room T is lower than the set temperature by at least 2°C (e.g.: 20°C are set and restarts when it drops to 18°C);
• during operation with an external thermostat, the contact of the latter controls the restart (e.g. in certain thermostats, the delta
can be set from 0.5°C to 1.5°C);
• N.B.: the above-mentioned conditions must remain stable for 10 consecutive seconds in order to exclude a temporary signal.
• The green LED ashes when restarted due to Eco-Stop (just like in a normal start-up).
• If the stove is switched o manually from the On/O key with the Eco-Stop function activated, the function will still remain active
when the stove is next started up.
• In the event of a black-out with the stove on and Eco-Stop active or in stand by due to Eco-Stop, the restore phase begins by shutting
down due to Eco being active and subsequently restarting (if the temperature is not reached, with a delay of 120 s).
Deactivation: briey press the On/O button 5 times consecutively within 6”. The board emits a long beep as conrmation (4 seconds).
ROOM THERMOSTAT CABLE  
POS.13