Installation manual
37
4-OPERATION
LED INDICATION TYPE OF PROBLEM SOLUTION
Led 2
The re failed to ignite Check the level of pellets in the hopper. Check that
the brazier rests correctly in its seat and has no visible
deposits of unburned pellets.
Led 1
The re goes o abnormally Check the level of pellets in the hopper. Check that
the brazier rests correctly in its seat and has no visible
deposits of unburned pellets.
Led 0
The pellet hopper temperature exceeds
the intended safety threshold.
The structure overheats due to reduced
heat dissipation.
Or
Triggered pressure switch
Wait for the cooling phase to be completed, cancel the
alarm and restart the product by setting the fuel load
to minimum on LED-2 and increasing the speed of the
room fan (knob A). If the alarm persists, contact the
service centre.
Check and clean the ENTIRE smoke duct-
Protect the outlet from any external wind.
Led +1
Abnormal smoke fan operation Verify that the brazier has no visible deposits of
unburned pellets. If the alarm persists, contact the
service centre.
Led +2
Smoke temperature too high or faulty
smoke probe.
Wait for the cooling phase to be completed, cancel the
alarm and restart the product by setting the fuel load
to minimum on LED-2 and increasing the speed of the
room fan (knob A). If the alarm persists, contact the
service centre.
SHUTDOWN MODE DUE TO AN ALARM
As from when the alarm is triggered, the appliance automatically enters the cooling phase, similar to that of shutdown mode, in order to
guarantee the system is cooled correctly and automatically cleaned.
Simply press key (D) to silence the buzzer without interrupting the cooling phase: the red LED turns orange and ashes and will go o once
the default shutdown temperature is reached.
The majority of the failed start-up and abnormal shutdown alarms can be cancelled by pressing key D once again, thereby switching to a
new ame ignition phase (after having loaded pellets into the hopper). Certain alarms can be cancelled, others require the intervention
of a specialised technician (previous table).
DELETING THE ALARM STATUS
If an alarm is triggered, normal product operation is restored by pressing the on/o key (D). If the cause that triggered he alarm does not
persist, after a brief verication, the product exits the alarm state and can restart.