INSTALLATION AND USER GUIDE PELLET STOVE PRIMULA ORCHIDEA GARDENIA MARGHERITA HYDRO MODEL Translation of original instructions EN
TABLE OF CONTENTS TABLE OF CONTENTS................................................................................................... II INTRODUCTION...........................................................................................................1 1-WARNINGS AND WARRANTY CONDITIONS..................................................................2 2-INSTALLATION INSTRUCTIONS...................................................................................
INTRODUCTION Dear Customer, our products are designed and manufactured in compliance with European reference Standards for construction products (EN13240 wood-burning stoves, EN14785 pellet-burning appliances, EN13229 fireplaces/wood-burning inserts, EN 12815 wood-burning cookers), with high quality materials and extensive experience in the transformation processes.
1-WARNINGS AND WARRANTY CONDITIONS • • • • • • • • • • • • 2 SAFETY PRECAUTIONS Installation, electrical connection, function test and maintenance must only be carried out by authorised and qualified personnel. Install the product in accordance with all local and national legislation and regulations in force in the region or state. A bad use or unproper maintainance of the product can bring to a serious risk of explosion in the combustion chamber. Only use the fuel recommended by the manufacturer.
1-WARNINGS AND WARRANTY CONDITIONS • • • • • • • • • • • • the Manufacturer from any civil and criminal liability. Any type of tampering or unauthorised replacement with non-original spare parts could be hazardous for the operator’s safety and relieves the company from any civil and criminal liability. Many of the surfaces of the product get very hot (door, handle, glass, smoke extraction pipes, etc.).
1-WARNINGS AND WARRANTY CONDITIONS • • • • • • • • • • • • • • 4 damage the electrical insulation and cause electric shocks. A carbon monoxide alarm must be fitted in the room where the appliance is sited Refer too ADJ part 2.34 through too 2.36 page 41 (ONLY FOR UK). If there is a fire in the flue pipe, extinguish the stove, disconnect it from the power supply and never open the door. Then contact the competent authorities.
1-WARNINGS AND WARRANTY CONDITIONS CE, VENTILATE THE ROOM AND CONTACT THE INSTALLER/ SERVICE ENGINEER IMMEDIATELY. INFORMATION • In case of any problems, get in touch with your dealer, or a qualified engineer authorised by MCZ, and if a repair is necessary, insist on the use of original spare parts. • Use only the fuel recommended by MCZ (for Italy pellets with a diameter of 6 mm and for other European countries with a diameter of 6-8 mm) and provided only with an automatic supply system.
1-WARNINGS AND WARRANTY CONDITIONS EXCLUSIONS The guarantee does not cover malfunctions and/or damage to the appliance that arise due to the following causes: • Damage caused during transportation or relocation • all parts that develop faults due to negligence or improper use, incorrect maintenance, installation that does not comply with the manufacturer’s instructions (always refer to the installation and use manual provided with the appliance) • incorrect dimensioning with regards to the use or faults in
1-WARNINGS AND WARRANTY CONDITIONS SPARE PARTS In the event of a malfunction, consult the retailer who will forward the call to the Technical Assistance Service. Use only original spare parts. The retailer or service centre can provide all necessary information regarding spare parts. We do not recommend waiting for the parts to be worn before having them replaced. It is important to perform regular maintenance.
1-WARNINGS AND WARRANTY CONDITIONS RULES FOR INSTALLATION The product in question is a stove that uses wood pellets. Below is a list of European regulations regarding the installation of the product: EN 12828 Heating systems design. IEC 64-8 Electrical systems with rated voltage not exceeding 1000 V AC and 1500 V DC.
2-INSTALLATION INSTRUCTIONS The instructions in this chapter refer explicitly to the Italian installation regulation UNI 10683. In any case, always observe the domestic regulations in force. PELLETS Wood pellets are manufactured by hot-extruding compressed sawdust which is produced during the working of natural dried wood. The compactness of the material is guaranteed by the lignin contained in the wood itself and allows pellets to be produced without glue or binders.
2-INSTALLATION INSTRUCTIONS FOREWORD The installation position must be chosen according to the room, to the smoke extraction system, to the chimney flue. Check with local authorities whether there are any restrictive regulations in force regarding the combustion air inlet, the smoke outlet system, the flue or the chimney cap.
2-INSTALLATION INSTRUCTIONS FOREWORD This chapter on the Smoke Flue has been produced in reference to the prescriptions of European regulations (EN13384 - EN1443 - EN1856 - EN1457). The chapter provides indications for installing an efficient and correct smoke flue but is under no circumstances to substitute the regulations in force, which the qualified technician must be in possession of.
2-INSTALLATION INSTRUCTIONS TECHNICAL CHARACTERISTICS Have the efficiency of the flue checked by an authorised technician. The flue must be sealed against flue gasses, in a vertical direction without narrowing, be made with materials impermeable to smoke, condensation, thermally insulated and suitable to resist normal mechanical stress over time (we recommend fireplaces made of A/316 or refractory material with insulated round section double chamber).
2-INSTALLATION INSTRUCTIONS ROOF AT 60° ROOF AT 45° B B C C D D E A F 60° A = MIN. 2.60 metres B = DISTANCE > 1.20 metres C = DISTANCE < 1.20 metres D = 0.50 metres ABOVE HIGHEST POINT E = 2.10 metres F = REFLUX ZONE FIGURE 5 A 45° A = MIN. 2.00 metres B = DISTANCE > 1.30 metres C = DISTANCE < 1.30 metres D = 0.50 metres ABOVE HIGHEST POINT E = 1.50 metres F = REFLUX ZONE E F FIGURE 6 DIMENSIONING The drop in pressure (draft) of a flue depends on its height.
2-INSTALLATION INSTRUCTIONS MAINTENANCE The flue must be kept clean, since the deposit of soot or unburned oils reduces the cross-section reducing the draft and thus compromising the efficient functioning of the heater and, if large build-ups accumulate, can catch fire. The flue and chimney must be cleaned and checked by a skilled chimney sweep at least once a year. Once the check/maintenance has been performed, request a signed report stating that the system is safe.
2-INSTALLATION INSTRUCTIONS EXTERNAL AIR INLET It is mandatory to provide an adequate external air intake that supplies the combustion air required for the product to work properly. The flow of air between the outside and the installation room may be direct, through an inlet in an external wall of the room; or indirect, via air intake from adjoining rooms and connecting permanently with the installation room (see Figure 9 b).
2-INSTALLATION INSTRUCTIONS DISTANCE (metres) The air inlet must be at a distance of: 1.5 m UNDER Windows, doors, smoke outlets, cavities, .... 1.5 m HORIZONTALLY Windows, doors, smoke outlets, cavities, .... 0.3 m ABOVE Windows, doors, smoke outlets, cavities, .... 1.5 m AWAY from smoke outlet CONNECTION TO FLUE The connection between the flue and the appliance must be via a smoke duct that conforms with EN 1856-2.
2-INSTALLATION INSTRUCTIONS EXAMPLES OF CORRECT INSTALLATION 1 U F E V I 2 1. Installation of Ø150mm flue with hole for the passage of the tube increased by: minimum 100 mm around the tube if next to non flammable parts such as cement, brick, etc.; or minimum 300 mm around the tube (or as prescribed by data tags) if next to flammable parts such as wood etc. In both cases, install suitable insulation between the flue and the ceiling.
3 - TECHNICAL DRAWINGS AND CHARACTERISTICS DRAWINGS AND CHARACTERISTICS DIMENSIONS OF PRIMULA AND ORCHIDEA HYDRO VERSION WITHOUT HOT WATER PRODUCTION KIT DIMENSIONS OF PRIMULA AND ORCHIDEA HYDRO VERSION WITH HOT WATER PRODUCTION KIT 18
3 - TECHNICAL DRAWINGS AND CHARACTERISTICS DIMENSIONS OF MARGHERITA ANDGARDENIA HYDRO VERSION Technical Dept.
3 - TECHNICAL DRAWINGS AND CHARACTERISTICS TECHNICAL CHARACTERISTICS Nominal output power Primula Hydro / Orchidea Hydro 21 kW (18060 kcal/h) Nominal output power (H2O) Minimum output power 17,0 kW (14620 kcal/h) 4,4 kW (3784 kcal/h) Minimum output power (H2O) 3,0 kW (2580 kcal/h) Efficiency at Max 92,5% Efficiency at Min 95% Temperature of exhaust smoke at Max 150 °C Temperature of exhaust smoke at Min 71 °C Particulate/OGC/Nox (13% O2) 2 mg/Nm3 - 0,2 mg/Nm3 - 132 mg/Nm3 (13% O2) CO at 13%
3 - TECHNICAL DRAWINGS AND CHARACTERISTICS TECHNICAL CHARACTERISTICS Nominal output power Margherita Hydro / Gardenia Hydro 11,6 kW (9976 kcal/h) Nominal output power (H2O) 10,0 kW (8600 kcal/h) Minimum output power 3,6 kW (3096 kcal/h) Minimum output power (H2O) 2,5 kW (2150 kcal/h) Efficiency at Max 91,5% Efficiency at Min 96% Temperature of exhaust smoke at Max 140 °C Temperature of exhaust smoke at Min 70 °C Particulate/OGC/Nox (13% O2) 11 mg/Nm3 - 3 mg/Nm3 - 168 mg/Nm3 CO at 13% O2at
4-INSTALLATION AND ASSEMBLY PREPARATION AND UNPACKING The Primula/Gardenia and Orchidea/Margherita stoves are delivered with two different types of packing: GARDENIA and PRIMULA stoves come in 1 pack • It contains the stove and also the steel sides with the profiles (fig.1) The ORCHIDEA and MARGHERITA stoves come in 2 packs • One contains the stove • One contains the ceramics (fig.2).
4-INSTALLATION AND ASSEMBLY The stove body or unit must always be kept in a vertical position when handled and moved by using carts only. Pay particular attention to the door and its glass, protecting them from mechanical knocks that would compromise their integrity. Always handle the product with care. If possible, unpack the stove near the chosen place of installation. The packaging materials are neither toxic nor harmful, and therefore no particular disposal measures are required.
4-INSTALLATION AND ASSEMBLY ASSEMBLING THE SIDE CLADDING ASSEMBLY OF PROFILES FOR INSERTION OF STEEL SIDES (PRIMULA) Remove, on the upper part, the cast iron top (A). Take the side (B) (make sure it goes into the part under the plugs (F) and secure it to the upper sheet metal of the stove with the bracket (C) and four screws (D). Two screws secure the bracket (C) on the stove and two secure the bracket (C) to the side (B). Repeat the same operation for both sides. Reposition the cast iron top.
4-INSTALLATION AND ASSEMBLY ASSEMBLY OF PROFILES FOR INSERTION OF STEEL SIDES (GARDENIA) Remove, on the upper part, the cast iron top (A). Take the two profiles (B) to be assembled on the front part of the stove (one to the right and one to the left). Make sure that the profile (B) at the bottom enters the hole predisposed for fixing on the base, and that along the side it enters the blade (B1) predisposed in the stove along its entire height.
4-INSTALLATION AND ASSEMBLY CERAMIC SIDES INSERTION (ORCHIDEA AND MARGHERITA) Remove, on the upper part, the cast iron top (A). Take the six ceramic sides (B) from the box and insert them onto the profile (C) in correspondence of the guide, from the top downwards. Repeat the same operation for both sides. Reposition the cast iron top. SIDES INSERTION We recommend using small velcro felt disks, to be applied to the ends of the ceramics to prevent contact between them.
5-PLUMBING CONNECTION PLUMBING SYSTEM CONNECTION IMPORTANT! If installation of the product involves interaction with another, pre-existing system complete with heating equipment (gas boiler, methane boiler, diesel boiler, etc.), contact qualified personnel, who subsequently will be responsible for conformity of the system in compliance with the applicable law in force.
5-PLUMBING CONNECTION CONNECTION DIAGRAM FOR GARDENIA-MARGHERITA HYDRO STOVE A1 A2 C E 3/4”M heating water delivery 3/4”M heating water return 3/4”M 3 bar 1/2” M safety valve 3/4”M system draining and emptying SYSTEM CONNECTIONS Make the connections to the corresponding fittings shown in the diagram on the previous page. Make sure the pipes are not placed under tension or undersized.
5-PLUMBING CONNECTION SYSTEM FILLING To fill the system, the stove can be equipped with an end piece (optional) with a check valve (D), for manual filling of the heating system (if the optional is not installed, the filling tap on the main boiler will be used). During this operation, any air in the system is released from the automatic vent valve located under the top. To allow the valve to vent, it is recommended to loosen the grey cap by one turn and leave the red cap locked (see figure).
5-PLUMBING CONNECTION WATER CHARACTERISTICS The characteristics of the water used to fill the system are very important to prevent the build-up of mineral salts and the formation of incrustations along the pipes, in the boiler and in the heat exchangers. Therefore, please ASK YOUR PLUMBER FOR HIS ADVICE CONCERNING: • • • • • Hardness of water circulating in the system, to prevent problems of incrustation and limescale, especially in the domestic water heat exchanger. (> 25° French).
6 - ELECTRICAL CONNECTIONS GENERAL PRECAUTIONS Electrical safety of the system is ensured only when it is properly connected to an efficient earthing system made in compliance with the safety standards in force: gas, water or heating systems pipes are not suitable as earth connections.
7 - INITIAL START-UP GENERAL PRECAUTIONS Remove all components that could burn from the brazier and glass (manual, various adhesive labels and any polystyrene). Check that the brazier is positioned correctly and rests properly on the base. After a long period of inactivity, remove any pellets left in the hopper (using a vacuum cleaner with a long pipe ), as they could have absorbed moisture, thereby altering their original characteristics and no longer being suitable for combustion.
7 - INITIAL START-UP Do not stand close to the product and air the room. The smoke and smell of paint will disappear after about an hour of operation, however, remember they are not harmful in any case. The boiler will be subject to expansion and contraction during the start-up and cooling phases, therefore slight creaking noises may be heard. This is absolutely normal as the structure is made of laminated steel and must not be considered a defect.
7 - INITIAL START-UP LOADING THE PELLETS Fuel is loaded from the upper part of the stove by opening the door. Pour the pellets into the hopper. To ease the procedure carry out the operation in two steps: Pour half of the contents into the hopper and wait for the fuel to settle on the bottom. Then complete the operation by pouring in the rest. Do not pour the pellets up to the gasket because otherwise the door does not close properly, so the stove is not airtight and the alarm is triggered.
8 - MENU ITEMS CONTROL PANEL DISPLAY Menu items 2 7 1 3 4 5 6 KEY 1. Boiler lighting/shutdown 2. Scrolling of programming menu to decrease. 3. Menu 4. Scrolling of programming menu to increase. 5. Decrease set temperature/programming functions. 6. Increase set temperature/programming functions. 7. Display. MAIN MENU It is accessed by pressing key 3 (menu).
8 - MENU ITEMS Timer setting (see relative chapter) Sleep setting (see relative chapter) SETTINGS MENU The SETTINGS menu allows to act on the boiler operating mode: a. Language. b. Cleaning (displayed only when the boiler is switched off). c. Feed screw loading (displayed only when the boiler is switched off). d. Tones. e. External thermostat (activation). f. Auto Eco (activation). g. Eco-Shutdown T (default 10 minutes). h. pump on T (default 50°C). i. Auxiliary boiler (default deactivated). j.
8 - MENU ITEMS c - Feed screw loading To select “Feed screw loading” (only when the boiler is switched off) act as follows: • Press the “menu” button. • Scroll to “Settings” using the arrows • Press “menu” to confirm. • Scroll to “Feed screw loading” using the arrows. • Press “menu” to confirm. • Select “Enable” with the + - keys. • Press “menu” to confirm and “esc” to exit. d - Tones This function is disabled by default, so to enable act as follows: • Press the “menu” button.
8 - MENU ITEMS h - Pump On T To select the Pump On T function act as follows: • Press the “menu” button. • Scroll to “Settings” using the arrows • Press “menu” to confirm. • Scroll to “Pump On T” using the arrows. • Press “menu” to confirm. • Modify the °C with the + - keys. • Press “menu” to confirm and “esc” to exit i - Auxiliary boiler One must install an additional module (optional) to enable start-up of an auxiliary boiler in the event the boiler is switched off or in alarm conditions.
8 - MENU ITEMS o - Components test To activate the “Components test” function (only when the boiler is switched off) act as follows: • Press the “menu” button. • Scroll to “Settings” using the arrows • Press “menu” to confirm. • Scroll to “Components test” using the arrows. • Press “menu” to confirm. • Select the test to be performed with the + - keys • Press “menu” to confirm and “esc” to exit p - Chimney sweep function To activate the “Chimney sweep” function act as follows: • Press the “menu” button.
8 - MENU ITEMS s - Technical menu To access the technical menu one must contact an assistance centre as one needs a password to enter. To intervene on the “technical menu” act as follows: • Press the “menu” button. • Scroll to “Settings” using the arrows • Press “menu” to confirm. • Scroll to “Technical menu” using the arrows. • Press “menu” to confirm. • Select “Product Type”, “Service”, “Parameters”, “DHW Parameters”, “Meters memories”, “Enable fan” and “Puffer data” with the + keys.
9 - PRELIMINARY NOTIONS SYSTEM CONFIGURATIONS DEPENDING ON THE MODEL Upon installation, the product must be set according to the type of system, selecting the appropriate parameter in the “SETTINGS” menu. The possible configurations are 5, as described below: Configuration Description 1 Room temperature management via the boiler probe or by enabling the external room thermostat. 2 2.
9 - PRELIMINARY NOTIONS CONFIGURATION 2.1 (FACTORY SETTING FOR VERSION WITH DOMESTIC HOT WATER - DHW) 5 4 5 2 6 3 7 1 CONFIGURATION 2.
9 - PRELIMINARY NOTIONS CONFIGURATION 3 5 4 5 6 11 8 12 9 2 3 7 1 CONFIGURATION 4 5 5 4 13 4 11 15 6 17 2 3 14 1 Technical Dept.
9 - PRELIMINARY NOTIONS CONFIGURATION 5 5 5 4 13 4 11 6 16 17 2 3 14 1 1 RED HYDRO STOVE 2 HEATING DELIVERY 3 HEATING RETURN 4 ZONE VALVES 5 HEATING BODIES 6 DOMESTIC HOT WATER 7 COLD DOMESTIC WATER 8 DOMESTIC WATER BOILER 9 DIVERTER VALVE 10 BOILER THERMOSTAT 11 THERMOSTATIC MIXING VALVE 12 DOMESTIC WATER 10 kΩ β3434 NTC PROBE 13 HEATING PUFFER 14 HEATING SYSTEM CIRCULATOR 15 PUFFER THERMOSTAT 16 PUFFER 10 kΩ β3434 NTC PROBE 17 SAFETY VALVE 44 7
9 - PRELIMINARY NOTIONS ONLY FOR UK RED GARDENIA/MARGHERITA/PRIMULA/ORCHIDEA HYDRO Technical Dept.
9 - PRELIMINARY NOTIONS ONLY FOR UK RED GARDENIA/MARGHERITA/PRIMULA/ORCHIDEA HYDRO 46
9 - PRELIMINARY NOTIONS ONLY FOR UK RED GARDENIA/MARGHERITA/PRIMULA/ORCHIDEA HYDRO Technical Dept.
9 - PRELIMINARY NOTIONS ONLY FOR UK RED GARDENIA/MARGHERITA/PRIMULA/ORCHIDEA HYDRO 48
10-OPERATION OPERATING MODE The operating mode for hydro boilers is AUTOMATIC only (manual mode is not envisioned). Flame modulation is managed according to the “System configuration” of the room probe placed on the rear of the appliance (see drawing), by the external thermostat, by the boiler water temperature or by the NTC probes. Technical Dept.
10-OPERATION EXTERNAL THERMOSTAT CONNECTION (e) EXTERNAL THERMOSTAT (not included with the boiler, to be provided by the user) The temperature of the boiler can also be controlled by an external room thermostat. It is located in a central position of the room where the boiler is installed. It provides a closer match between the heating temperature requested of the boiler and what it actually provides. POS.1-2 EXTERNAL THERMOSTAT POS.5 EARTHING POS.3-4 PUFFER/BOILER PROBE POS.
10-OPERATION START-UP Press key 1 (esc) to begin start-up, the control panel displays ON with a flashing flame. When the flame stops flashing the boiler has reached the “power output” operating mode. The room temperature set by default is 20°C, if one wishes to change it act as instructed in the adjustments menu; act likewise to set the heating water temperature and the room fan speed (if envisaged). To activate external thermostat if any see the relative section.
10-OPERATION PROGRAMMED MODE (TIMER) - Main menu Setting the current day and time is essential for the proper operation of the timer. There are six TIMER programmes, for each one the user can decide the start-up and shutdown time as well as the day of the week in which it is active.
10-OPERATION NOTES FOR TIMER OPERATION • Start-up with the timer always takes place with the last temperature and ventilation settings (or with default 20°C and V3 settings in the event they have never been changed). • Start-up time ranges from 00:00 a 23:50 • If the shutdown time is not already memorised, it proposes a start-up time in + 10 minutes. • A timer programme switches the boiler off at 24:00 of one day and another programme switches it on at 00:00 of the next day: the boiler stays on.
10-OPERATION AUXILIARY BOILER (see section 8i) One must install an additional module (optional) to enable start-up of an auxiliary boiler in the event the stove is switched off or in alarm conditions. By default this function is deactivated, if needed activate it to access the settings menu. PELLETS RECIPE (see section 8j) This function is for adapting the stove to the pellets that are being used.
10-OPERATION SEASON FUNCTION (see section 8p) In configurations 2 and 3, by enabling the “summer” function, the deviation of the 3-way valve to the heating system is inhibited in order to prevent the radiators from heating up, therefore the flow is always directed towards the domestic hot water (DHW) - if envisaged. By activating the “summer” option one automatically enables the auto-eco function (it cannot be deactivated). The room probe/external thermostat are not taken into account.
11-SAFETY DEVICES AND ALARMS SAFETY DEVICES The product is supplied with the following safety devices PRESSURE SWITCH Monitors pressure in the smoke duct. It is designed to shut down the pellets feed screw in the event of an obstructed flue or significant back-pressure. (wind) SMOKE TEMPERATURE PROBE Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the preset value.
11-SAFETY DEVICES AND ALARMS TAMPERING WITH THE SAFETY DEVICES IS PROHIBITED If the product is NOT used as described in this instruction manual, the manufacturer declines all liability for any damage caused to persons and property.
11-SAFETY DEVICES AND ALARMS ALARM ALERTS Whenever an operating condition other than that designed for the regular operation of the boiler occurs, there is an alarm condition. The control panel gives information on the reason of the alarm in progress. A sound signal is not envisioned for alarms A01-A02 only so to not disturb the user in the event of pellets running out in the hopper during the night. Panel alert Type of problem Solution A01 The fire does not ignite.
11-SAFETY DEVICES AND ALARMS NORMAL SHUTDOWN (on the panel: OFF with flashing flame) If the shutdown key is pressed or if there is an alarm signal, the boiler goes into the thermal shutdown phase which entails the automatic execution of the following stages: • It stops pellets loading • The room fan (if provided) maintains the set speed until the smoke T reaches 100°C, then it automatically sets itself at the minimum speed until it reaches the shutdown temperature • The smoke fan sets itself at maximum spe
12-RECOMMENDATIONS FOR A SAFE USE RECOMMENDATIONS FOR A SAFE USE ONLY A SUITABLE INSTALLATION ACCORDING TO THE UK BUILDING REGULATIONS (ADJ) AND A PROPER MAINTAINANCE AND CLEANING OF THE PRODUCT CAN ASSURE YOU THE CORRECT FUNCTIONALITY AND A SAFE USE OF YOUR STOVE(ONLY FOR UK). We wish to notify you that we have been made aware of incidents involving domestic heating pellet stoves resulting from the stoves having been incorrectly installed or inadequately maintained.
13-MAINTENANCE AND CLEANING EXAMPLE OF A CLEAN BRAZIER EXAMPLE OF A DIRTY BRAZIER Only a proper maintainance and cleaning of the product can assure you the correct functionality and a safe use of your stove. ATTENTION! All the cleaning operations of all parts must be performed with the product completely cold and the plug disconnected. Disconnect the product from the 230V power supply before performing any maintenance operation.
13-MAINTENANCE AND CLEANING CLEAN THE EXCHANGER AND THE UNDERGRATE SPACE EVERY 2/3 DAYS. Cleaning the exchanger and the undergrate space is a simple operation but very important for always maintaining performance as declared.
13-MAINTENANCE AND CLEANING PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN CLEANING THE HEAT EXCHANGER Half-way through the winter season, but especially at the end of it, the compartment through which the exhaust smoke passes will need to be cleaned. This cleaning process is mandatory in order to facilitate the general removal of all combustion residue, before it becomes very difficult to remove it due to the humidity compacting it over time.
13-MAINTENANCE AND CLEANING CLEANING THE EXCHANGER AND PIPE UNIT (GARDENIA/MARGHERITA) CLEANING THE UPPER COMPARTMENT When the stove is cold, remove the top, remove the ceramics/sides, by loosening the relative fastening screws before removing the drivers “B” and then remove the boiler cover “C” At this point, remove the four turbulators “D” and using a rigid rod or a bottle brush, clean the internal pipe unit and the turbulators, removing all of the accumulated ash.
13-MAINTENANCE AND CLEANING ATTENTION: The frequency with which the smoke exhaust must be cleaned depends on the use of the stove and the type of installation. We recommend contacting an authorised service centre for end-of-season maintenance and cleaning as the abovementioned operations will be performed together with a general inspection of the components.
13-MAINTENANCE AND CLEANING REPLACEMENT OF OVERPRESSURE SILICON DAMPER FOR COMBUSTION CHAMBER The overpressures sillicon damper “G” for combustion chamber (fig. A) shall be replaced with a new one yearly (during the periodical maintainance) in order to keep the overpressure safety system efficient. For replacement use the following instructions • remove the top • remove the first lateral ceramic covering / metal covering (in accordance with the model) • unscrew the screw-washer-damper-spacer shown in fig.
14-PROBLEMS/CAUSES/SOLUTIONS CHECKING THE INTERNAL COMPONENTS ATTENTION! The internal electromechanical components must only be checked by qualified personnel whose technical expertise includes combustion and electricity. It is recommended to perform this routine maintenance annually (with a scheduled service contract), which focuses on a visual and functional verification of the internal components. The following is a summary of the necessary checks and/or maintenance for the product to work correctly.
15-PROBLEMS/CAUSES/SOLUTIONS ATTENTION: All repairs must only be carried out by a specialised technician, with the product switched off and the plug disconnected. If the product is NOT used as described in this instruction manual, the manufacturer declines all liability for any damage caused to persons and property. ANOMALY POSSIBLE CAUSES Pellets are not being fed into The pellet hopper is empty the combustion chamber. Sawdust has blocked the feed screw SOLUTIONS Fill the hopper with pellets.
15-PROBLEMS/CAUSES/SOLUTIONS ANOMALY POSSIBLE CAUSES Pellets accumulate in the brazier, the Insufficient combustion air. glass of the door gets dirty and the flame is weak. Clean the brazier and check that all the holes are clear. Perform a general cleaning of the combustion chamber and the smoke duct. Check that the air inlet is not obstructed. Damp or unsuitable pellets. Change the type of pellets. Faulty smoke evacuation motor. Check the motor and replace it, if necessary.
15-PROBLEMS/CAUSES/SOLUTIONS ANOMALIES RELATED TO THE PLUMBING SYSTEM ANOMALY POSSIBLE CAUSES No increase in temperature with Incorrect combustion adjustment. stove in operation. Boiler/system dirty. Condensation in boiler. Radiators cold in winter. SOLUTIONS Check recipe. Check and clean the boiler. Insufficient stove power. Check that the stove is properly sized for the requirements of the system. Poor pellets quality. Use of manufacturer pellets. Incorrect temperature setting.
16-WIRING DIAGRAM ELECTRICAL DIAGRAM OF PRIMULA/ORCHIDEA – MARGHERITA/GARDENIA Hydro WITHOUT DOMESTIC HOT WATER KIT LIVE ELECTRIC CABLES DISCONNECT THE 230 V POWER CABLE BEFORE CARRYING OUT ANY OPERATION ON THE CIRCUIT BOARDS MOTHERBOARD WIRING KEY 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13.
16-WIRING DIAGRAM ELECTRICAL DIAGRAM OF PRIMULA/ORCHIDEA Hydro WITH DOMESTIC HOT WATER KIT LIVE ELECTRIC CABLES DISCONNECT THE 230 V POWER CABLE BEFORE CARRYING OUT ANY OPERATION ON THE CIRCUIT BOARDS MOTHERBOARD WIRING KEY 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13.
16-WIRING DIAGRAM ELECTRICAL DIAGRAM OF PRIMULA/ORCHIDEA - MARGHERITA/GARDENIA Hydro WITH HIGH EFFICIENCY PUMP 27 26 23 LIVE ELECTRIC CABLES DISCONNECT THE 230 V POWER CABLE BEFORE CARRYING OUT ANY OPERATION ON THE CIRCUIT BOARDS MOTHERBOARD WIRING KEY 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14.