EGT PROBE SPECIFICATIONS
Thermocouple type ‘K’
Range -148 to 2372°F (-100 to 1300°C)
Accuracy: +/-0.4% of reading or about +/- 1.1°C (Special Limits of Error)
Probe diameter: 3/16 inch (0.187 inch) (4.75 mm)
Sensing Junction Enclosed, Ungrounded
Response Time 1200 mS
Time Constant Defined as the time required to reach 63.2% of an instantaneous
temperature change. Five time constants are required to approach 100 % of
the step change value
Outer Sheath Material Inconel, melting point 2550°F (1400°C)
Cable Stainless steel over braiding over Teflon™ insulated, stranded wires, 20
gauge
Compression Fitting 316 stainless steel, adjustable, 1/8 inch NPT male thread*
Wiring + = Yellow, - = Red
* ¼ NPT Thread Compression fitting and steel bung available to Purchase at www.redarc.com.au
23mm
76mm
50mm 53mm2000mm
O4.75mm
1⁄8th NPT
76mm
Sensor Location