G52-TTT G52-TTT Dual Temperature 52mm Gauge (With Optional Temperature Display)* G52-TTT TEMP C 0 150 120 150 120 90 60 90 60 0 C *Optional Temperature Display requires the purchase of GS-UT-80 / GS-UT-120 / GS-OWT1-4 or GS-OWT1-8
WARNING & SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS - This manual contains IMPORTANT SAFETY INSTRUCTIONS for the G52-TTT Gauge. DO NOT OPERATE THE GAUGE UNLESS YOU HAVE READ AND UNDERSTOOD THIS MANUAL AND THE GAUGE IS INSTALLED AS PER THESE INSTALLATION INSTRUCTIONS. NOT SUITABLE FOR MARINE APPLICATIONS. 1. The G52-TTT Dual Temperature Gauge is designed to provide an accurate indication of Oil and/or Water temperatures with an optional temperature indicator.
INSTALLATION Find a suitable location for mounting the Gauge. REDARC offer a range of mounting solutions - refer to www.redarc.com.au . It is important to ensure that your installation meets any regulations regarding Field of View and Head Impact requirements.
OPERATING INSTRUCTIONS Selecting Gauge ID for multi-gauge systems If your gauge is part of a multi gauge system (i.e. more than one gauge) and you wish to allow programming from a single push button, connect the communication link wires together (see wiring diagram on page 2). The Gauge “Id” of all linked gauges will need to be set to unique numbers. Make sure that each gauge is set to a unique number or letter and that one gauge is set as the master “Id.0”.
OPERATING INSTRUCTIONS Setup Modes (Setup mode is indicated by display of the programming symbol TEMP C 0 150 150 120 120 90 90 60 60 0 C TEMP C 0 150 150 120 120 90 90 60 60 0 C TEMP C 0 150 150 120 120 90 90 60 60 0 C TEMP C 0 150 150 120 120 90 90 60 60 0 C TEMP C 0 150 150 120 120 90 90 60 60 0 C TEMP C 0 150 120 150 120 90 60 90 60 0 C ) ID Select Mode / Beeps: 1 Selections: 0 to 9 & A to F (16 selections) For a single gauge setup do not chan
OPERATING INSTRUCTIONS Setup Modes TEMP C 0 150 150 120 120 90 90 60 60 0 C 0 150 120 120 90 90 60 60 0 C TEMP C 0 150 150 120 120 90 90 60 60 0 C TEMP C 0 150 150 120 120 90 90 60 DO NOT ADJUST THE OPTIONAL TEMP DISPLAY READING UNLESS THE SENSOR IS AT A STABLE AND KNOWN TEMPERATURE. Press and hold to slowly increase the temperature reading until it matches the known temperature of the sensor.
FREQUENTLY ASKED QUESTIONS Centre black circle on gauge is flashing intermittently. If the black centre ring is flashing and the gauge sounds an alarm, the gauge may have been programmed to trigger a relay, but a relay is not detected. Check the relay connection or reprogram as required. If no relay output is required refer to setup mode 11 and select ‘nc’.