Manual

16
2 USER GUIDE
2.1.4 Power Saving Load Adjustment
Figure 2.1.4.1 - Power Saving Load Adjustment
The user can adjust the potentiometer to set the input sleep and wake-up
thresholds according to the load applied. The setting range is shown below:
Model
Minimum
(Potentiometer turned fully anti-clockwise)
Maximum
(Potentiometer turned fully clockwise)
Sleep Power Wake Up Power Sleep Power Wake Up Power
700/1000/1500/2000W <20W >40W <110W >160W
3000W <40W >60W <240W >280W
2.1.5 TRC Port (RJ45)
Not currently used.
Potentiometer Rotation
Wake Up Power
Sleep Power
Anti-Clockwise
160
40
110
20
Clockwise
Power (W)
700-2000W Models
Potentiometer Rotation
Wake Up Power
Sleep Power
Anti-Clockwise
280
160
240
110
Clockwise
Power (W)
3000W Models
D