Table 2.2.4.1 - Recommended Cable & Fuse Sizing (12V Install)
12V Inverter 700W 1000W 1500W 2000W 3000W
Fuse Size (A) 125 175 225 250 450
Recommended Fuse Mega Mega Mega Mega Mega
Cable length Cable Size mm² (AWG)
0 - 1m 27 (3) 54 (O) 85 (OOO) 105 (OOOO) 120*
1 - 2m 27 (3) 54 (O) 85 (OOO) 105 (OOOO) 120*
2 - 3m 34 (2) 68 (OO) 85 (OOO) 105 (OOOO) x
3 - 4m 54 (O) x 105 (OOOO) 120 x
4 - 5m 68 (OO) x 120 x x
5 - 6m x x x x x
Fuse ratings are suitable to these recommended minimum cable sizes.
* High temperature (110°C) or higher rated cable is required.
Table 2.2.4.2 - Recommended Cable & Fuse Sizing (24V Install)
24V Inverter 700W 1000W 1500W 2000W 3000W
Fuse Size (A) 50 70 100 150 225
Recommended Fuse Midi Midi Midi Midi/Mega Mega
Cable length Cable Size mm² (AWG)
0 - 1m 8 (8) 13 (6) 21 (4) 34 (2) 85 (000)
1 - 2m 8 (8) 13 (6) 21 (4) 34 (2) 85 (000)
2 - 3m 13 (6) 13 (6) 21 (4) 34 (2) 85 (000)
3 - 4m 13 (6) 21 (4) 27 (3) 42 (2) 85 (000)
4 - 5m 21 (4) 27 (3) 34 (2) 54 (0) 85 (000)
5 - 6m 21 (4) 34 (2) 42 (1) 68 (00) 105 (0000)
Fuse ratings are suitable to these recommended cable sizes.