Manual

1 CONNECTIONS
Connection
Name
Connector pin
locations
Function
AUX STATUS
LAMP
1 Dash Warning LED lamp output. Use low-
current LED lamp.
VIN+ 3 12/24V positive power supply.
OUTPUT
TRIGGER
5 Isolation switch control output. Switches to
ground on rollover.
Redarc BMIS
Trigger enable
6 Trigger enable for Redarc BMIS
VIN- 8 Ground connection for electronics.
Do not connect other pins: they are reserved for future use.
Recommended Crimping Tool: Tool 58529-1 (TE - Pro Crimper III)
Die Assembly 58529-2
4
1 2 3
6 7 8
4 5
Rear View
Insert terminals with
cables attached.
Ensure pin is fully
inserted.
Push until end stop.
Pull cable to test retention.
Close red cap
until 'click' is felt.