Product Manual

THE SMART START
®
SBI
The Smart Start
®
SBI is a microprocessor controlled Smart Battery Isolator. The Smart Start
®
SBI is
designed specifi cally for use in multi battery applications as a solenoid priority system to protect the
start battery from being excessively discharged by auxiliary loads, whilst still allowing the auxiliary
battery to supply non essential loads. Put simply, once the start battery has had some charge from the
alternator, the Smart Start
®
SBI will connect an auxiliary battery to the charge circuit. Similarly, if the
start battery voltage drops too low, the Smart Start
®
SBI will disconnect any auxiliary batteries or loads
from the start battery to conserve charge.
SPECIFICATIONS
Part Number SBI12 (D)* SBI24 (D)* SBI212 (D)* SBI224 (D)*
System Voltage 12V 24V 12V 24V
ON Volts 13.2V 26.4V 13.2V 26.4V
OFF Volts 12.7V 25.4V 12.7V 25.4V
Turn ON Delay 5 sec 5 sec 5 sec 5 sec
Turn OFF Delay 10 sec 10 sec 10 sec 10 sec
Max. Cont. Current 100 Amps 100 Amps 200 Amps 200 Amps
Max. Inrush Current 400 Amps 400 Amps 600 Amps 600 Amps
Standby Current < 5mA < 5mA < 5mA < 5mA
Dimensions 75x70x80mm 90x95x100mm
Weight 200g 600g
Warranty 2 years
Standards CE, C-Tick, AS/NZS CISPR11:2004
*D indicates “Dual Sensing” which is described on page 4.
CABLE SIZE, CIRCUIT BREAKER(CB)/FUSE SIZE AND STUD TORQUE CHART
Model Wire
Length
Start Feature with
Pushbutton Override
No Override Main Stud
Torque
CB or Fuse Wire CB or Fuse Wire
SBI12/
SBI24
Up to 3m 100 Amps 19mm² (4B&S) 60 Amps 8mm² (8B&S) 5 - 6.2 Nm
3m to 6m 100 Amps 32mm² (2B&S) 60 Amps 13mm² (6B&S) 5 - 6.2 Nm
SBI212/
SBI224
Up to 3m 200 Amps 32mm² (2B&S) 120 Amps 19mm² (4B&S) 6.5Nm max
3m to 6m 200 Amps 40mm² (1B&S) 120 Amps 25mm² (3B&S) 6.5Nm max
1
SAL.FOR.Instruction Manual.SBI – DOC424 – Version 12