Product Manual

19
2 INSTALLATION GUIDE
2.6.3 Charger Connection (BCDC)
The BCDC should be mounted as close as possible to the Distribution Box. Connect
the BCDC’s battery output positive (+) and Ground (
) to the Distribution Box
Charger (+) and Ground (-) connections.
Refer to Section 2.3 for cable sizing.
The Distribution Box includes a 50A MIDI fuse to protect the charging circuit (the
maximum charging current is 40A). Refer to Section 2.5 for details.
Auxiliary Battery
Supplied
Fuse
Black
Brown