Product Manual

21
2 INSTALLATION GUIDE
2.8 R-Bus Connection (Manager 15 or 30)
2.8.1 Connecting the RedVision R-Bus
RedVision uses an R-Bus communication system to link components.
1. Use the supplied 1 metre RJ45 cable to connect the Battery Management System to
either of the sockets on the Distribution Box.
2. Use the 5 metre RJ45 cable to connect the remaining socket on the Distribution Box
to the Display.
3. Fit the Terminating Resistor to the remaining socket in the Display.
4. When a Manager 15 or 30 is used, the terminating resistor for the other end of the
Bus is inbuilt in the BMS. If a Manager 15 or 30 is not used, the supplied terminating
resistor should be inserted into one of the ports on the TVMS1280-DB (Distribution
Box).
BMS
Battery Sensor
T-Piece
Terminating
Resistor
Display