2.10 Optional Inverter Connection
REDARC’s RS-Series inverters may be connected to the Distribution Box to allow the
user to monitor power consumption, output load and switch the inverter on/off, all via the
Display. Note that the 350W model inverter (R-12-350RS) offers power on/off control only.
The inverter should be mounted as close as possible to the Auxiliary battery (Refer to the
inverter’s user manual for further installation information including fuse and cable sizing.
Risk of damage to the system. Do NOT connect to the ‘TRC’ socket at the front (240V
end) of the inverter as this will cause damage to the RedVision system. Connect to the
‘REMOTE’ socket to avoid damage.
1. Connect the non-overmoulded end of the supplied RJ12 cable to the ‘REMOTE’
socket at the Rear (12V end) of the inverter.
2. Connect the over-moulded end of the supplied RJ12 cable to the to the inverter input
of the Distribution Box.
3. Connect the Inverter DC supply to the battery, NOT a load output of the Distribution
Box
For further information about REDARC inverters visit:
http://redarcqr.com/inverters
To ‘REMOTE’ Socket
at Rear (12V end)