Product Manual

10
2 INSTALLATION GUIDE
2.2 Mounting Instructions
The Distribution Box should be mounted as close as possible to the auxiliary
battery(s) and Battery Charger to avoid voltage drop.
2.2.1 Mounting the Distribution Box
The Distribution Box may be mounted in any orientation but must be mounted
onto a fl at, solid surface using 4 x M6 screws or bolts. Failure to adequately
mount the unit, such as using adhesives to mount the unit may result in unreliable
operation of the Distribution Box. Ensure clear access to the fuse panel to ensure
service of fuses and override of channels can be performed.
±15°
±30°
4 x M6