Product Manual

15
2 INSTALLATION GUIDE
2.4 Digital I/Os
1
3
2
The Distribution Box incorporates 3 digital inputs.
The digital inputs,
1
,
2
and
3
, can be confi gured to switch Distribution Box output
loads on/off when triggered (for example, to turn off all loads except a fridge when the
vehicle ignition is on).
The Start Battery Positive (
) and Start Battery Negative ( ) inputs can be used
to monitor and display a voltage from an external source (for example, to display the
vehicle’s starter battery voltage).
Start Battery Positive
Start Battery Negative
1
2
3
Digital Inputs