SPECIFICATIONS
Model BWH30NLTE-2
Ignition Piezo Ignitor
Gas Type Natural Propane
BTU/Hr Input Max. (available)
30,000 30,000
BTU/Hr Input Min. (available)
15,000 24,000
Pressure Regulator Setting 4" W.C. 9" W.C.
Inlet Gas Pressure*
(inches of water)
Max. 9.5" Max. 14"
Min. 5" Min. 11"
Heater Dimensions (HxWxD) 24.1" x 25.5 x 8.46"
Carton Dimensions (HxWxD) 26.18" x 28.15" x 9.84"
Heater Weight 27.6 lbs
Shipping Weight 31.9 lbs
Electrical Requirement for Blower Kit (included)
Voltage • 120 VAC, 60 Hz
Note: Dimensions listed are outer most points on the
heater (includes control knobs and grill).
* For purposes of input adjustment.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot shuts off the heater if there is not
enough fresh air.
THERMOSTATIC CONTROL
The control automatically cycles the burner
on and off to maintain a desired room
temperature.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
Propane/LP or Natural gas. The heater is
shipped from the factory ready for connect-
ing to Propane/LP. The heater can easily be
changed to Natural gas by having your quali-
ed installer follow the instructions on page
13 and the markings on the heater.
LOCAL CODES
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
This heater is designed for vent-free op-
eration. State and local codes in some areas
prohibit the use of vent-free heaters.
State of Massachusetts: The installation
must be made by a licensed plumber or
gas tter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-red supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts the gas
cock must be a T-handle type. The State
of Massachusetts requires that a exible
appliance connector cannot exceed three
feet in length.