Owner's manual

22
1. IMPORTANT
1.1 This appliance should be installed according to regulations
in force and only used in a well-ventilated space. Read
these instructions before installing or operating.
1.2 The Redfyre Universal must be installed by a competent
person and this person must be an OFTEC trained and
registered engineer.
1.3 The person(s) who installs this appliance, commissions,
services and carries out remedial work (e.g. electrical fault
finding), must have suitable engineering qualifications.
1.4 The Traditional is supplied in kit form to be assembled on
site.
1.5 Engineers carrying out the assembly must be trained by
Redfyre.
1.6 There is a manual detailing how to assemble the cookers
correctly which forms part of these Installation Instructions.
This is only supplied to officially trained engineers. Please
contact Redfyre for further details.
2. HEALTH & SAFETY
2.1 Redfyre takes every reasonable care to ensure products
are designed and constructed to meet all general safety
requirements when properly used and installed. This
standard means products are comprehensively tested and
examined before despatch.
2.2 Note the points and items listed under 2.3, 2.4 and 2.5. It
is the Engineer’s responsibility to ensure protective cloth-
ing or equipment is worn for personal health and safety
when handling hazardous materials.
2.3 Glass rope, mineral wool, insulation pads, ceramic fibre,
glass insulation, can be harmful if inhaled, irritating skin,
eyes, nose or throat. On handling, avoid inhalation and
contact with eyes by using disposable gloves, face masks
and eye protection. When disposing, reduce dust with
water spray and ensure parts are securely wrapped. Wash
hands and other exposed parts after handling. When dis-
posing, reduce dust with water spray and ensure parts are
securely wrapped.
2.4 The glues, sealants and paints of this product present no
known hazards if used in the manner anticipated.
2.5 This appliance is heavy and care must be taken when
installing.
KEROSENE & GAS OIL FUELS (MINERAL OILS)
2.6 The effect of mineral oils on the skin vary according to the
duration of exposure. The lighter fractions also remove the
protective grease normally present on the surface of the
skin rendering the skin dry, liable to cracking and more
prone to damage caused by cuts and abrasions.
INSTALLATION INSTRUCTIONS
INSTALLATION
2.7 Skin rashes (oil acne). Seek immediate medical attention
for any rash, wart or sore developing on any part of the
body.
2.8 Avoid, as far as possible, any skin contact with mineral oil
or with clothing contaminated with mineral oil.
2.9 Never breathe any mineral oil vapors. Do not fire the
Burner in the open i.e. out of the Cooker as a misfire will
cause unburnt oil vapors.
2.10 Barrier cream containing lanolin is highly recommended
together with a strict routine of personal cleaning.
2.11 Under no circumstances should mineral oils be taken inter-
nally.
3. UNIVERSAL (WITH AN ELECTRIC HOB
AND ELECTRIC OVENS
WIRING EXTERNAL TO THE APPLIANCE MUST BE IN
ACCORDANCE WITH THE CURRENT IEE WIRING
REGULATIONS, ELECTRICITY AT WORK REGULATIONS
AND ANY LOCAL REGULATIONS.
3.1 The appliance must be connected by a competent person,
using fixed wiring via a DOUBLE POLE SWITCHED 45 amp
OUTLET with a minimum contact clearance of 3 mm.
IMPORTANT
The wires in this mains lead are coloured in accordance
with the following code:
- green/yellow Earth
- blue Neutral
- brown Live
If the mains lead needs replacing we recommend that the
operation is carried out by a qualified electrician replacing it
with a lead of the same size and temperature rating.
POWER SUPPLY
Note: the power supply can be rated at 30 amp of the cooker is
fitted without an electric hob.
-