Place 1/8” setting blocks as shown or approximately every 18”. DO NOT
place setting blocks over screw heads. Using suction cups slide the
Fixed Panel Glass into the appropriate side. Use setting blocks to make
exposed edges of the glass level and plumb. Exposed edges MUST be
level and plumb before moving to next step.
Using the glass clamp mounting slot on the Fixed Panel Glass as a
guide, make a mark on the wall on center w/ the slot. Remove the
Fixed Panel Glass and carefully set aside, leaving the setting blocks in
position.
**Different size setting blocks may be required depending on level
conditions. Various size setting blocks are provided and can be used
in different combinations (stacked) to obtain the desired results.
Drill one 3/16” diameter hole at the mark just made. Drill
through tile and backer board. Do not drill through block-
ing.
Note: This must be done just before Wall Mount Clamp
installation.
Disassemble the Wall Mount Clamp, and place the cover
plate and screw aside. Place the clamp on the wall, with
the finished side of the clamp plate toward the inside of
the shower, and secure it to the wall with a #8 x 1-1/2
truss head screw.
Note: Do not over tighten screw.
SLOT
MARK ON