70-00058-01-04 Proprietary Redline Communications © 2010 Page 27 of 136 April 19, 2010
Figure 8: System - AN-100UX Front Panel
3.1.1 Mounting
The indoor equipment can be freestanding on a flat surface or in a 19-inch rack.
3.1.2 Power Supply
The AN-100U and AN-100UX (high power) equipment have different power supply
features. Read the following section carefully to determine the correct power
requirements and options. All models feature double pole/neutral fusing. Refer to the
Installation Guidelines manual for additional information about DC power wiring.
Warning to service personnel:
Caution for all AC and DC models Double Pole/Neutral fusing.
AN-100U
Power supply options include single or dual AC or DC supplies, or a combination of AC
and DC power supplies. Cables are included with both AC and DC power supplies.
Table 7 - IDU Installation - RedMAX AN-100U Power Specifications
Voltage range
[V]
Tolerance
[%]
Power
consumption
max. [W]
Max.
Current
[A]
Inrush
current
1
[A]
AC Input
2
100-240 VAC
10%
75
2
35
DC Input
2
24-60 VDC
20%
75
6
40
1. Typical Inrush current is less then 500 us. DC: measured, AC: P/S manufacturers data.
2. Auto-sensing.