4.4.3 Management Interface
Click Management Interface in the system menu (left side of screen) to view and edit
the IP address and DHCP settings.
Figure 31: Web: Configuration - Management Interface Screen
IP Parameters
Obtain IP Parameters from DHCP Server: Select this option to have the base station
obtain its IP address from a DHCP server.
Use the following IP Parameters: Manually enter the following IP parameters:
IP Address: Enter the static base station network IP address.
Subnet Mask: Enter the base station subnet address mask.
Default Gateway: Enter the IP address of the default gateway on the local Ethernet
segment.
Time Server (SNTP): Enter the IP address of the SNTP server.
Use the following checklist to ensure correct display options:
1. Time server must be compatible with SNTP (RFC-2030)
2. Ensure the time zone is correct for your area.
3. If you are in an area that observes daylight savings time, check the box.
Time Zone: Enter the time offset from GMT (hours:minutes).
Daylight Savings: Check to enable automatic time change for daylight savings.
Syslog Server: Enter the IP address of the Syslog server to enable this feature.
Refresh: Click Refresh Time to poll the time server for the current time.