Table 34: System Log Messages
Log Message Description
211-Error: while writing flash!
While writing the new software into terminal flash memory,
an unexpected error occurred. Try to repeat the process and
if the error persists, contact your local representative.
212-Error firmware configuration! An unexpected error occurred while writing the onboard
firmware configuration. Try to repeat the process.
213-Firmware programming
failed!
The firmware programming failed.
214-Error while loading version
control!
Software version control data was not loaded successfully.
215-Log buffer full! The log buffer overflowed.
216-Invalid Options Key! User entered an invalid Product Options key.
217- PLL unlocked! One or more RF synthesizers unlocked. The unit stopped
RF transmissions and attempted to reprogram the
synthesizers. If this message repeats or if the RF link is not
back on, try to reset the terminal. If the problem persists,
contact customer support.
218-Outdoor unit over
temperature!
The internal temperature of the transceiver is above 185F /
85C. The transceiver shuts down for thirty seconds to allow
cooling.
219-Excessive DC loss on IF
cable!
The DC voltage at the transceiver (carried by the IF cable
from the terminal) is lower than the required 24 VDC. Check
the IF cable and connectors.
220-Outdoor unit power supply
fault!
Displays a fault in the transceivers power supply. This error
could be due to a problem with the internal power supply, or
with the power source from the terminal. If error 219
(Excessive DC loss on IF cable) is also indicated, check the
IF cable and connectors. Otherwise, the transceiver requires
servicing.
221-\public\ community cannot
be deleted!
The default Public SNMP community cannot be deleted.
222-Max. community number
already defined!
No more communities may be defined, as the maximum
number has been reached
223-Community name already
defined!
The name for the SNMP community has already been used.
Choose another name.
224-MIB initialization error! MIB construction process generated an error. Try to reset
the terminal. If the problem persists, contact customer
support.
225-Error while loading SNMP
configuration!
EEPROM memory was corrupted and the SNMP
configuration could not be loaded. Default SNMP
configuration was loaded.
226-Error while saving SNMP
configuration!
SNMP configuration saving process was not successfully.