User's Manual

AN-30e
user manual
70-00035-01 Proprietary Redline Communications © 2004 November 2004
Page 95 of 104
TDM Save Command Error Codes
The error code returned by an unsuccessful save command contains three fields:
LEVEL + NUMBER + ERROR_ID
Table 53: TDM Save Command Error Codes
Level
Number Error
ID
Definition
0
GENERAL_SYNCON
Too many bundles: if user defines more than
the internal bundle limit for the current
software release
1
GENERAL_TOO_MANY_BUNDLES
Line type (T1 or E1) is disabled in option key
0
(General)
Always 0
2
GENERAL_LINE_TYPE
Error at syncon parameter: if clocking is
loopback and the serial interface selected for
synchronization has no bundles defined, or if
clocking is adaptive and there is no exactly
one bundle defined
0
SERIAL_BUNDLES_OVERLAP
Bundles defined on the serial line 'x' have
timeslots overlapping, x=1…4
1
SERIAL_TOO_MANY_BUNDLES
The serial line 'x' is unframed and the user
defined more than one bundle, x=1…4
2
SERIAL_CODING
Wrong line coding for the serial line 'x',
x=1…4
1
(Serial)
x
Number of
misconfigured
serial
interface
(1-4)
3
SERIAL_FRAMING
Wrong line framing for the serial line 'x',
x=1…4
0
BUNDLE_TS0
The bundle 'y' contains timeslot 0 and the
corresponding serial line is framed, y=1…128
2
(Bundle)
y
Number of
the
misconfigured
bundle
(1-128)
1
BUNDLE_MASK
Too many timeslots selected for bundle 'y',
y=1…128