5.2.2 Remote-end System Settings
The following remote-end system parameters must be set prior to operation of the
wireless portion of the system. Refer to section 6.3: System Configuration Screens
on page 49 for additional details of these fields.
Table 7: Required Configuration Settings - Remote-end system
Item Description
Ethernet
IP address
Network address of the AN-50e remote-end system (must be unique).
IP Subnet
Mask
Network subnet mask.
Default
Gateway
Default router/gateway on the local Ethernet segment.
Ethernet
Mode
Select the operating mode of the Ethernet port (auto-negotiate, 10/100
Mbps).
Wireless
Master
Mode
Ensure that the Master Mode check box is not checked (
).
RF Freq.
[MHz]
Enter the channel center frequency of the system.
TX Power
[dBm]
Enter the default transmit power level (dBm). Refer to section 8.3:
Antenna and Power Specifications on page 82.
If the TX power levels are restricted by local regulations, the maximum
Tx power available will be limited to this value.
Auto Scan
Check this box
to enable the remote-end System to automatically
scan for the frequency of the AN-50e Master (system with Master
Mode setting enabled).
DFS Action
Select the mode of operation for dynamic frequency selection (DFS).
If the DFS function is required by local regulations, then DFS will be
set on and this selection will be disabled.
DFS
Antenna
Gain
Enter the antenna gain (dBm). This value must be set to match the
System antenna.
ATPC
Enable
Check this box
to enable the Automatic Transmit Power Control
function.
Adaptive
Modulation
Check this box
to enable adaptive modulation mode.
Radio
Enable
Check this box
to enable the radio transmitter.