8.5. System Statistics
Clicking on System Status in the main menu will load this page, which provides General
Information, Ethernet LAN Statistics and Wireless Statistics of the unit of interest, as
shown in Figure 22.
Figure 22: System Status
General:
Status Code: An global error code indicating the condition of different components
within the AN-50 terminal and T-58 Transceiver as well as the status of all links and
connections involving the terminal. See error list below for details:
AN-50 PLL Error: The PLL (Phase Locked Loop) section within the AN-50 terminal
experienced an error. The System Fault LED may light. Try resetting the unit.
Communication Error Over IF Cable: Communication between the AN-50
terminal and the T-58 Transceiver failed. Check the IF cable and connectors.
Radio High Temp. Warning: The T-58 Transceiver’s internal temperature rose
above 185F / 85C. The transceiver will shut down for 30 seconds to allow cooling
time.
Radio Power Supply Fault: Indicates a fault in the transceiver’s power supply. This
error could be due to a problem with the internal power supply, or with the power
source from the AN-50 terminal. If the Low DC Voltage At Radio error is also
indicated, (see below) check the IF cable and connectors. If the Low DC Voltage At
Radio error is not indicated, the T-58 Transceiver will require servicing.
Low DC Voltage At Radio Input: The DC voltage at the transceiver (carried by the
IF cable from the AN-50 terminal) is lower than the required 24VDC. Check the IF
cable and connectors. The minimum required voltage for operation is 12VDC.
Cable Attenuation: Indicates the attenuation of the signal over the IF cable.
Registered Station: Shows the total number of configured links. If the AN-50 operates
in PTP mode this field will display one.
Configured Connection: Shows the total number of configured connections. If the AN-
50 operates in PTP mode this field will display one.