User's Manual

AN-50 System User Manual
Redline Communications …..solving the first mile challenge.
All four Ethernet LEDs light for one second, then individual Ethernet LEDs blink twice in
the following order: 100, FD, Col, Link. The Fault LED lights for approximately four
seconds, then turns off. The two Wireless LEDs remain off for approximately five
seconds, then blink once and resume their normal state.
The remainder of this section lists possible problems that may occur and the
corresponding remedies.
9.1.1. System Power
If the Pwr LED is not illuminated solid green, power is not
getting to the unit. The most probable causes are:
Table 3: System Power Diagnostics
Symptom Possible Problem Solution
On/Off switch in Off position Turn on switch at back of unit.
Fuse blown Replace fuse. (spares provided)
Pwr LED does
not illuminate
Power cord disconnected Securely connect cord to terminal
and outlet.
To replace a fuse, pop the black plastic cover located on the back panel beside the
power switch, and extract the red fuse holder. Be certain to replace the fuse(s) into the
lower half of the holder, as shown in the diagram below. The fuse holder holds two
fuses, both of which are active. Be certain to use fuses of the same type and rating.
Note space