User's Manual

RedCONNEX
TM
AN-80i
PTP & PMP User Manual
70-00072-01-04-DRAFT Proprietary Redline Communications © 2007 May 7, 2007
Page 76 of 91
6.3 Testing and Saving System Parameters
The AN-80i is a highly configurable communications device. All configurable options
are saved in non-volatile RAM. The system configuration and snmp settings are saved
separately.
6.3.1 CLI Interface
Use the 'test' command to have the AN-80i load the edited settings. The AN-80i will
operate with these settings for a period of five minutes. During the test period, you may
click the Save button at any time to save this configuration permanently. Otherwise, after
five minutes, the AN-80i will reboot and load the previously saved settings.
Note: Factory defaults can only be restored using the CLI commands.
Figure 37: Diag - Saving Parameters in NVRAM
6.3.2 Web Interface
The Test button is located on the System Configuration page. Click this button to have
the AN-80i load the current settings displayed in the configuration screen. The AN-80i
will operate with these settings for a period of five minutes. During the test period you
may click the Save button at any time to save this configuration permanently (also
terminating the five minute timer). After five minutes, if the Save function button has not
been applied, the AN-80i will reboot and load the previously saved settings.