3.8 AN-80i Product Options Screen
Click Product Options in the left hand menu to display the Product Options screen.
You may not be able to establish a link between AN-80i units, or configure all required
parameter settings until you have entered the permanent options key. Permanent options
keys must be purchased and are provided in electronic format. The options key (a string
of numbers, letters, and dashes) enables AN-80i features including the maximum
uncoded burst rate and frequency ranges (region codes). Every options key is unique to
an AN-80i unit.
Each new AN-80i received from the factory will contain a temporary options key. This
temporary key may provide temporary access to advanced options and settings. When the
factory options key expires, only limited service will be available (restricted RF
frequency, data rates, etc).
Important: A permanent Options Key must be entered for in-service operation: the
temporary options key shipped with the system will expire and service will be
interrupted.
Figure 10: Web - Product Options Screen
Entering the Options Key
1. Enter the key (case sensitive).
2. Verify that the entered value is correct
3. Click the Activate button.
4. Click System Log in the menu and verify the key has been accepted.