4.2 Connecting via Telnet
To connect to the AN-80i, open a Telnet session to the IP address of the AN-80i. On a
Windows™ PC, open the Run command and type 'telnet' followed by the IP address of
the AN-80i. When the command prompt screen appears, login to the AN-80i. The AN-
80i may now be controlled using a set of CLI commands.
Figure 17: CLI - Connecting via Telnet
The system will logout users automatically if no commands are received (idle) for five
minutes. To exit immediately from the CLI, type the following command:
logout [ENTER]
4.3 CLI Command Set
4.3.1 Chgver
Use the chgver command to change the software version to loaded when you reboot the
AN-80i. Also see the Get command 'swver'.
Table 9: CLI - chgver
Command Parameter/Description
chgver
Enter this command to toggle between software versions. The setting will
alternate between the two banks of memory (no parameters).
chgver <Enter>
4.3.2 Get
Use the get command to view system parameters. Use the following general format to
view a parameter:
get [field] <Enter>
Table 10: CLI - get
Command Parameter/Description
get
calcdst: Calculated link distance between units.
erxpkt: Number of Ethernet packets received.
erxpktd: Number of Ethernet packets received that were discarded.
etxpkt: Number of Ethernet packets transmitted.
mac: AN-80i MAC address.
radiotype: Radio type.
rffreq: Current RF frequency setting.
rflink: Status of the RF link.