5.5 Status Codes
The AN-80i reports the following conditions using the Status Code field. See 3.4: System
Status on page 18.
Table 23: Diag. - Status Codes
Error Type Error #
(Hexadecimal)
Description
Tx Power 0x0001 Power output is less than 10 dBm.
RF High Temp.
Warning
0x0002 The transceiver internal temperature rose above
185F / 85C. The transceiver will shut down for 30
seconds to allow cooling.
RF PLL Lock
Error
0x0010 The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
PHY lock error 0x0020 The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
80 MHz PLL lock
error
0x0040 The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
Firmware
Configuration
Error
0x0100 Error detected in the AN-80i configuration file.