Installation Manual

RDL-2000 User Manual
70-00143-01-01a Proprietary Redline Communications © 2010 Page 45 of 50 September 20, 2010
Table 9: CLI - Command Summary
the Telnet session.
To upgrade the firmware, the computer hosting the Telnet session must also
have a TFTP server. The firmware file must be located in the TFTP servers
default directory (can not specify a path). When the transfer has completed
successfully, use the switchbanks command to enable the new software
version.
Example: Upload the software binary file abc.brn to the inactive bank on the RDL-2000:
[192.168.25.2] >>: firmware abc.brn
id <id_value>
View or modify the RDL-2000 Master identifier (MU ID). This identifier ensures the
slave established a link only with the designated Master. The identifier is in MAC-
address format.
[blank] - Display current ID.
id_value - Specify the ID for this unit.
Example: Set the RDL-2000 ID to 0050c24f7fd2:
[192.168.25.2] >>: id 0050c24f7fd2
ip <address>
View or modify the RDL-2000 IP address.
[blank] - Display current IP address.
address - Specify the new IP address for this unit.
Example: Set the RDL-2000 IP address to 192.168.20.25:
[192.168.25.2] >>: ip 192.168.20.25
logger <off> <on>
Change the logger settings. When enabled, the logger feature sends all RDL-2000
event messages directly to the screen running the CLI session. All CLI commands
remain available while the logger feature is enabled.
off - Disable the logger.
on - Enable he logger.
Example: Enable the logger:
[192.168.25.2] >>: logger on
mgmtvid <VID>
View or modify the RDL-2000 management VLAN ID setting.
When security is enabled, the RDL-2000 can be managed only using VLAN traffic
tagged with the value specified in the mgmtvid field.
[blank] - Display current VLAN ID.
address - Specify the new VLAN ID for this RDL-2000.
Example: Set the RDL-2000 VLAN ID to 12:
[192.168.25.2] >>: mgmtvid 12
power
View the current RDL-2000 TX power output. When automatic controls are enabled,
the displayed value may be different than the TX Power setting in the Link Manager
Installation->Advanced screen.
Example: Display the current Tx power setting:
[192.168.25.2] >>: power