User's Manual

RDL-2000 User Manual
70-00143-01-01a Proprietary Redline Communications © 2010 Page 30 of 50 September 24, 2010
UL Rate: (Master only) Select the UL modulation/coding for the wireless link. The RDL-
2000 will receive using only the selected modulation/coding. Identical settings must be
used on the Master and Slave. When Adaptive Modulation is enabled, this setting is
ignored.
Channel BW: Select the RF channel bandwidth. Settings include 5, 10, 20, and 40 MHz
(based on Regional setting). Identical settings must be used on the Master and Slave.
Enable MIMO: Check this box to enable the MIMO feature (and the transceiver for
RF Port 2). This setting must be enabled for use of a 2 x 2 MIMO antenna system.
Identical settings must be used on the Master and Slave.
Current Rate
Displays the current DL and UL modulation/coding.
Get Parameters: Click this button to read the current settings from the RDL-2000.
Submit Parameters: Click this button to send the current parameter settings on this
screen to the RDL-2000. The RDL-2000 will save these settings in non volatile RAM. All
unsaved changes are discarded when the operator changes to another screen.