Schematics

MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
Page 108 of 173
REPORT No.SZ21020185W03
2.7.3. Test Result
The maximum conducted interference is searched using Peak (PK), if the emission levels more
than the AV and QP limits, and that have narrow margins from the AV and QP limits will be
re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power
mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded
points and plots below.
Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested
respectively, only the results of the worst case AC 120V/60Hz were recorded in this report.
A.Test Setup:
Test Mode: EUT+ ADAPTER + WIFI TX
Test Voltage: AC 120V/60Hz
The measurement results are obtained as below:
E [dBμV] =U
R
+ L
Cable loss
[dB] + A
Factor
U
R
: Receiver Reading
A
Factor
: Voltage division factor of LISN